Abstract: Several factors drive the need for increased efficiency in telemedicine screening programs directed toward diabetic retinopathy: continually increasing prevalence of diabetes worldwide, growing awareness among physicians and patients of the importance of early detection of retinal damage, and emerging technology in artificial intelligence that enables rapid identification of vision-threatening fundus features. In this context, optimizing workflows in teleretinopathy programs becomes a priority. Recent work has revealed opportunities for improvement in areas of logistics, in particular in finding the best way to get diabetic patients in front of screening cameras as conveniently as possible, as this improves compliance and, ultimately, achieves the widest reach for detection programs. The present review discusses particular aspects of mobile screening programs in which specialized retinal cameras are deployed in a van or similar type of vehicle so that they can reach patients anywhere in order to reduce barriers to access. The rationale for implementing such programs and practical considerations are presented, along with a view toward future expansion of screening and integration with artificial intelligence platforms. Lacking standardization of format and quality control among smartphone-linked approaches at present, translation of eye clinic-based photographic techniques to community-based screening offers a means of expanding the scope of impactful screening programs without the need for adoption of significantly new technology.
Background: Using a randomized controlled trial (RCT), to assess the efficacy of the folded technique of self-adherent wrap to eyes after orbital tumour extirpation and compare it with the classic technique.
Methods: A single-centre, prospective, randomized, controlled study was conducted among 128 patients who underwent orbital tumour extirpation in this study. The folded and classic techniques of applying self-adherent wraps were randomly allocated to patients (1:1). The primary endpoint was the interface pressure on the affected eye. Secondary efficacy endpoints were the interface pressure above and below the ear of the affected side, above the ear of the non-affected side, and discomfort scores. Postoperative complications were observed for 24 hours.
Results: The interface pressure with the folded technique on the affected eye was neither inferior nor superior to the classic technique (1.33±0.07 vs. 1.41±0.09 mmHg, P=0.480). Most importantly, the pressure at three other points outside of the affected eye, including above and below the ear of the affected side, and above the ear of the non-affected side, were significantly higher when using the classic technique than when using the folded technique (P=0.041, 0.019, and 0.047, respectively). Discomfort scores were higher in the classic technique group than in the folded technique group (2.93±0.30 vs.1.52±0.19, P≤0.001).
Conclusions: Findings demonstrated the advantages of using folded technique to apply self-adherent wrap for wounds after orbital tumour extirpation with lower interface pressure outside of the affected eye and patient discomfort scores, without influencing pressure on the affected eye comparing with the classic technique.
Abstract: Anthropometry can analyze the size, weight, and proportion of the human body objectively and quantitatively to supplement the visual assessment. Various non-invasive three-dimensional (3D) anthropometric techniques have been applied to assess soft tissues’ 3D morphology in the clinical practice. Among them, non-invasive stereophotogrammetry and laser scanning techniques are becoming increasingly popular in craniofacial surgery and plastic surgery. They have been applied for craniofacial growth estimation and morphometric investigation, genetic and acquired malformation diagnosis, as well as orthodontic or surgical treatment arrangement and outcome evaluation. However, few studies have been published for assessing the 3D morphology of soft tissues in the periorbital region. This paper reviews the studies involving the application and evaluation of the increasingly popular 3D photogrammetry in the periorbital region. These studies proposed detailed and standardized protocols for three-dimensionally assessing linear, curvilinear, angular, as well as volumetric measurements, and verified its high reliability in the periorbital region (even higher than caliper-derived direct measurements). In the future, reliable and accurate 3D imaging techniques, as well as standardized analyzing protocols, may find applications in following up morphological growth, preoperatively diagnosing and assessing patient periorbital conditions, planning surgical procedures, postoperatively evaluating treatment outcomes of a specific procedure, and comparing the differences in surgical results between various procedures, studies, as well as populations.
Abstract: Glaucoma is a group of eye diseases that seriously threaten human visual health. Increased intraocular pressure is the main clinical manifestation and diagnostic basis of glaucoma and is directly related to increased resistance to aqueous circulation channels. The trabecular meshwork (TM) is a multi-layer spongy tissue that filters aqueous humor. Its structure changes and the filtering capacity decreases, leading to an increase in intraocular pressure. Surgical methods for TM are constantly updated. Compared with traditional glaucoma surgical techniques, such as external trabeculectomy, the development of a new surgical technique—minimally invasive glaucoma surgery (MIGS)—enables the operation to reduce intraocular pressure efficiently while further reducing damage to the eye. MIGS achieves the purpose of surgery mainly by optimizing the TM outflow pathway, uveoscleral outflow pathway, and subconjunctival outflow pathway. A new surgical instrument, the Kahook Dual Blade, appears to optimize the TM outflow pathway in the surgical technique. The Kahook Dual Blade is a new type of angle incision instrument. Because of its unique double-edged design, in the process of goniotomy, it can effectively reduce the damage to the anterior chamber angle structure and accurately remove the appropriate amount of TM so that the aqueous humor can flow out smoothly. Kahook Dual Blade goniotomy has the advantages of avoiding complications and foreign body sensation caused by intraocular implants. The operation time is relatively short, the surgical technique is easy to master, and the TM resection scope can be determined based on the patient’s condition. It can be used to treat some clinically meaningful glaucoma. This article is organized as follows. We present the following article following the Narrative Review reporting checklist.
Abstract: Eyelid surgery is widely and extensively used in facial plastic and reconstructive surgeries. There are many categories of eyelid surgeries, the most common of which include blepharoplasty, ptosis surgery, and eyelid reconstruction. In many cases, these procedures are combined, and there are many different techniques for each type of operation. Upper eyelid blepharoplasty usually includes the excision of skin, preseptal orbicularis oculi muscle, and orbital fat. Common methods of lower eyelid blepharoplasty are the skin-muscle flap, the skin flap, and the transconjunctival. Ptosis surgery is mainly divided into three types: transcutaneous, transconjunctival, and sling surgery. Surgeons often used the Hughes or Cutler-Beard Bridge Flaps in eyelid reconstruction. Different types and methods of surgery have their own advantages and disadvantages, and postoperative complications may occur. Therefore, postoperative complications of eyelid surgeries, such as dry eye symptoms, should be taken into serious consideration. Relevant literature involving these complaints can be found in PubMed by searching the terms “dry eye”, “eyelid”, “surgery”, and other related keywords. Moreover, various ocular surface and tear film alterations may be detected using the Ocular Surface Disease Index (OSDI), tear film breakup time, Schirmer test, fluorescein staining, and lissamine green staining after various eyelid surgeries. As dry eye disease is prevalent in the general population, it is more urgent to figure out what we can learn from these complaints. Further exploration in this field may help surgeons to choose a better surgical method and give an accurate evaluation of the postoperative effect.
Perception is the ability to see, hear, or become aware of external stimuli through the senses. Visual stimuli are electromagnetic waves that interact with the eye and elicit a sensation. Sensations, indeed, imply the detection, resolution, and recognition of objects and images, and their accuracy depends on the integrity of the visual system. In clinical practice, evaluating the integrity of the visual system relies greatly on the assessment of visual acuity, that is to say on the capacity to identify a signal. Visual acuity, indeed, is of utmost importance for diagnosing and monitoring ophthalmological diseases. Visual acuity is a function that detects the presence of a stimulation (a signal) and resolves its detail(s). This is the case of a symbol like “E”: the stimulus is detected, then it is resolved as three horizontal bars and a vertical bar. In fact, within the clinical setting visual acuity is usually measured with alphanumeric symbols and is a three-step process that involves not only detection and resolution, but, due to the semantic content of letters and numbers, their recognition. Along with subjective (psychophysical) procedures, objective methods that do not require the active participation of the observer have been proposed to estimate visual acuity in non-collaborating subjects, malingerers, or toddlers. This paper aims to explain the psychophysical rationale underlying the measurement of visual acuity and revise the most common procedures used for its assessment.
Background: Retinal degeneration is a common feature of several retinal diseases, such as retinitis pigmentosa and age-related macular degeneration (AMD). In this respect, experimental models of photo-oxidative damage reproduce faithfully photoreceptor loss and many pathophysiological events involved in the activation of retinal cell degeneration. Therefore, such models represent a useful tool to study the mechanisms related to cell death. Their advantage consists in the possibility of modulating the severity of damage according to the needs of the experimenter. Indeed, bright light exposure could be regulated in both time and intensity to trigger a burst of apoptosis in photoreceptors, allowing the study of degenerative mechanisms in a controlled fashion, compared to the progressive and slower rate of death in other genetic models of photoreceptor degeneration.
Methods: Here, an exemplificative protocol of bright light exposure in albino rat is described, as well as the main outcomes in retinal function, photoreceptor death, oxidative stress, and inflammation, which characterize this model and reproduce the main features of retinal degeneration diseases.
Discussion: Models of photo-oxidative damage represent a useful tool to study the mechanisms responsible for photoreceptor degeneration. In this respect, it is important to adapt the exposure paradigm to the experimental needs, and the wide range of variables and limitations influencing the final outcomes should be considered to achieve proper results.
Trial Registration: None.