Background and Objective: Limbal stem cell deficiency (LSCD) is characterized by the insufficiency of limbal stem cells to maintain the corneal epithelium. Severe cases of LSCD may be treated with limbal transplantation from healthy autologous or allogeneic limbal tissue. Multiple cell-based therapies have been studied as alternative treatments to improve success rates and minimize immunosuppressive regimens after allogeneic transplants. In this review, we describe the success rates, and complications of different cell-based therapies for LSCD. We also discuss each therapy’s relative strengths and weaknesses, their history in animal and human studies, and their effectiveness compared to traditional transplants.Methods: PubMed was searched for publications using the terms LSCD, cell-based therapy, cultivated limbal epithelial transplantation (CLET), cultivated oral mucosal epithelial transplantation (COMET),and mesenchymal stem cells from 1989 to August 2022. Inclusion criteria were English language articles.Exclusion criteria were non-English language articles.Key Content and Findings: current cell-based therapies for LSCD are CLET and non-limbal epithelial cells. Non-limbal epithelial cell methods include COMET, conjunctival epithelial autografts, and mesenchymal stem/stromal cells (MSCs). Moreover, several alternative potential sources of non-limbal cells have described, including induced pluripotent stem cells (iPSCs), human embryonic stem cells (hESCs),human dental pulp stem cells, hair follicle bulge-derived epithelial stem cells, amniotic membrane epithelial cells, and human umbilical cord lining epithelial cells.Conclusions: Cell-based therapies are a promising treatment modality for LSCD. While CLET is currently the only approved cell-based therapy and is only approved in the European Union, more novel methods have also been shown to be effective in human or animal studies thus far. Non-limbal epithelial cells such as COMET are also an alternative treatment to allogeneic transplants especially as a surface stabilizing procedure. iPSCs are currently being studied in early phase trials and have the potential to revolutionize the way LSCD is treated. Lastly, cell-based therapies for restoring the limbal niche such as mesenchymal stem cells have also shown promising results in the first human proof-of-concept study. Several potential sources of non-limbal cells are under investigation.
Although amniotic membrane transplantation (AMT) has long been used as an essential surgical technique for ocular surface reconstruction, its role continues to evolve and expand. In the management of numerous ocular surface disorders, ranging from inflammatory to infectious, traumatic to neoplastic, the ability to perform AMT is a valuable addition to the skillset of any ophthalmologist. The purpose of this paper is to provide ophthalmologists with an updated, evidence-based review of the clinical indications for AMT in corneal and conjunctival reconstruction, reviewing its common and even experimental applications known to date. The methods of amniotic membrane preservation, the available commercial amniotic membrane products to date, and future directions for amniotic membrane use, including amniotic membrane extract eye drops (AMEED), are also discussed. It is paramount for ophthalmologists to stay up-to-date on the applications of AMT so as to effectively incorporate this versatile treatment modality into their practice,both in the operating room and in the clinic. By familiarizing the general ophthalmologist with its diverse applications, we hope to motivate general ophthalmologists to incorporate the use of AMT into their clinical practice, or provide guidance on how to recognize when referral to a corneal specialist for amniotic membrane application is prudent.
Background: Benign essential blepharospasm (BEB), aberrant facial nerve degeneration and hemifacial spasm (HFS) are all examples dystonia which, though not life-threatening, can have a significant impact on patient quality of life. The need for reliable self-rating surveys to monitor functional disability is fundamental. The Blepharospasm Disability Index (BSDI) is already a widely utilised and validated self-rating score for blepharospasm whilst the functional disability score (FDS) requires further validation. The principle aim of this study is to repeat validation of the FDS against the BSDI, which has been validated by several groups since its original description but only in patients with BEB.Methods: A randomised blinded prospective cohort study was conducted at a single unit on 38 patients with BEB, aberrant facial nerve degeneration and HFS. Patients were blinded to complete the FDS followed by the BSDI or the BSDI followed by the FDS with a 30-minute interval.Results: Both the FDS and BSDI were found to be reliable with high internal consistency and test-retest reliability. Both scales were also found to be moderately correlated with the Jankovic disease severity score.Conclusions: This study is the first to use the FDS as a rating scale in patients with HFS and aberrant facial nerve degeneration. It is also the first study to formally validate the FDS as an acceptable rating scale for patients with dystonia and in particular it provides validation for its use in patients with HFS and aberrant facial nerve degeneration.
The prevalence of diabetic retinopathy (DR) continues to increase in pregnant females; these individuals are also at a higher risk of disease progression. The lack of evidence regarding the safety and efficacy of current treatment options in pregnancy makes disease management particularly challenging.All pregnant women with diabetes should have a prenatal DR screening, as well as receive counseling regarding the progression and management of DR during pregnancy. Optimal blood glucose and blood pressure control should be encouraged. For patients with proliferative diabetic retinopathy (PDR) in the absence of visually significant diabetic macular edema (DME), panretinal photocoagulation (PRP) remains a safe and effective treatment option. Visually significant DME can be treated with focal laser if areas of focal leakage are identified in the macula on fluorescein angiogram, intravitreal steroids or anti-vascular endothelial growth factor (VEGF) agents, The theoretical risk of anti-VEGF agents to the fetus should be considered and the patients should be extensively counselled regarding the risks and benefits of initiating anti-VEGF therapy before initiating treatment. When the decision is made to treat with anti-VEGF agents, Ranibizumab should be the agent of choice. In conclusion, ophthalmologists should make treatment decisions in pregnant patients with DR on a case-by-case basis taking into consideration disease severity, risk of permanent threat to vision, gestational age, and patient preferences.
Background: Necrotising fasciitis (NF) is a rare but severe necrotising infection of the subcutaneous tissues. We report a case of periocular NF associated with a concurrent COVID-19 infection and explore potential mechanisms of pathogenesis of COVID-19 infection and necrotising superinfections.
Case Description: A 33-year-old previously healthy female presented with right-sided progressive periocular swelling, erythema, pain and fever, two days after sustaining a laceration to the right superolateral brow from a clenched fist. She had a concurrent COVID-19 infection, detected on nasopharyngeal polymerase chain reaction swab thirteen days prior to presentation and again at presentation. She did not have an oxygen requirement. There was a large bulbous collection of the right upper lid with fluctuance and overlying erythema, and a communicating sinus drained frank pus from the superolateral brow. Pre-operative T2-weighted MRI demonstrated fascial hyperintensity involving the pre-septal tissues and extending to the anterior temporal fossa. She was commenced on intravenous meropenem, clindamycin and vancomycin, and underwent early surgical debridement. Initial debridement demonstrated right upper lid necrosis involving the dermal and pre-septal layers, including the orbicularis, but sparing the tarsus. Streptococcus pyogenes was isolated, and she was continued on a prolonged course of intravenous antibiotic. Periocular defects were repaired with a right-sided brow adipo-fascial flap based on the supratrochlear artery, browpexy and dual full thickness skin grafts on the right upper lid and flap.
Conclusions: NF is an acute fulminant infection rarely affecting the periocular tissues. This represents a unique case of periocular NF associated with a concurrent COVID-19 infection.
Backgrounds: To assess changes in anterior segment biometry during accommodation using a swept source anterior segment optical coherence tomography (SS-OCT).
Methods: One hundred-forty participants were consecutively recruited in the current study. Each participant underwent SS-OCT scanning at 0 and ?3 diopter (D) accommodative stress after refractive compensation, and ocular parameters including anterior chamber depth (ACD), anterior and posterior lens curvature, lens thickness (LT) and lens diameter were recorded. Anterior segment length (ASL) was defined as ACD plus LT. Lens central point (LCP) was defined as ACD plus half of the LT. The accommodative response was calculated as changes in total optical power during accommodation.
Results: Compared to non-accommodative status, ACD (2.952±0.402 vs. 2.904±0.382 mm, P<0.001), anterior (10.771±1.801 vs. 10.086±1.571 mm, P<0.001) and posterior lens curvature (5.894±0.435 vs. 5.767±0.420 mm, P<0.001), lens diameter (9.829±0.338 vs. 9.695±0.358 mm, P<0.001) and LCP (4.925±0.274 vs. 4.900±0.259 mm, P=0.010) tended to decreased and LT thickened (9.829±0.338 vs. 9.695±0.358 mm, P<0.001), while ASL (6.903±0.279 vs. 6.898±0.268 mm, P=0.568) did not change significantly during accommodation. Younger age (β=0.029, 95% CI: 0.020 to 0.038, P<0.001) and larger anterior lens curvature (β=?0.071, 95% CI: ?0.138 to ?0.003, P=0.040) were associated with accommodation induced greater steeping amplitude of anterior lens curvature. The optical eye power at 0 and ?3 D accommodative stress was 62.486±2.284 and 63.274±2.290 D, respectively (P<0.001). Age was an independent factor of accommodative response (β=?0.027, 95% CI: ?0.038 to ?0.016, P<0.001).
Conclusions: During ?3 D accommodative stress, the anterior and posterior lens curvature steepened, followed by thickened LT, fronted LCP and shallowed ACD. The accommodative response of ?3 D stimulus is age-dependent.
Background: Dyop® is a dynamic optotype with a rotating and segmented visual stimulus. It can be used for visual acuity and refractive error measurement. The objective of the study was to compare refractive error measurement using the Dyop® acuity and LogMAR E charts.
Methods: Fifty subjects aged 18 or above with aided visual acuity better than 6/12 were recruited. Refractive error was measured by subjective refraction methods using the Dyop® acuity chart and LogMAR E charts and the duration of measurement compared. Thibo’s notation was used to represent the refractive error obtained for analysis.
Results: There was no significant difference in terms of spherical equivalent (M) (P=0.96) or J0 (P=0.78) and J45 (P=0.51) components measured using the Dyop® acuity and LogMAR E charts. However, subjective refraction measurement was significantly faster using the Dyop® acuity chart (t=4.46, P<0.05), with an average measurement time of 419.90±91.17 versus 452.04±74.71 seconds using the LogMAR E chart.
Conclusions: Accuracy of refractive error measurement using a Dyop® chart was comparable with use of a LogMAR E chart. The dynamic optotype Dyop® could be considered as an alternative fixation target to be used in subjective refraction.
Contrast is the differential luminance between one object and another. Contrast sensitivity (CS) quantifies the ability to detect this difference: estimating contrast threshold provides information about the quality of vision and helps diagnose and monitor eye diseases. High contrast visual acuity assessment is traditionally performed in the eye care practice, whereas the estimate of the discrimination of low contrast targets, an important complementary task for the perception of details, is far less employed. An example is driving when the contrast between vehicles, obstacles, pedestrians, and the background is reduced by fog. Many conditions can selectively degrade CS, while visual acuity remains intact. In addition to spatial CS, “temporal” CS is defined as the ability to discriminate luminance differences in the temporal domain, i.e., to discriminate information that reaches the visual cortex as a function of time. Likewise, temporal sensitivity of the visual system can be investigated in terms of critical fusion frequency (CFF), an indicator of the integrity of the magnocellular system that is responsible for the perception of transient stimulations. As a matter of fact, temporal resolution can be abnormal in neuro-ophthalmological clinical conditions. This paper aims at considering CS and its application to the clinical practice.
Perception is the ability to see, hear, or become aware of external stimuli through the senses. Visual stimuli are electromagnetic waves that interact with the eye and elicit a sensation. Sensations, indeed, imply the detection, resolution, and recognition of objects and images, and their accuracy depends on the integrity of the visual system. In clinical practice, evaluating the integrity of the visual system relies greatly on the assessment of visual acuity, that is to say on the capacity to identify a signal. Visual acuity, indeed, is of utmost importance for diagnosing and monitoring ophthalmological diseases. Visual acuity is a function that detects the presence of a stimulation (a signal) and resolves its detail(s). This is the case of a symbol like “E”: the stimulus is detected, then it is resolved as three horizontal bars and a vertical bar. In fact, within the clinical setting visual acuity is usually measured with alphanumeric symbols and is a three-step process that involves not only detection and resolution, but, due to the semantic content of letters and numbers, their recognition. Along with subjective (psychophysical) procedures, objective methods that do not require the active participation of the observer have been proposed to estimate visual acuity in non-collaborating subjects, malingerers, or toddlers. This paper aims to explain the psychophysical rationale underlying the measurement of visual acuity and revise the most common procedures used for its assessment.