BJO专栏

Universal artificial intelligence platform for collaborativemanagement of cataracts (authorized Chinese translation)

:665-675
 
Objective: To establish and validate a universal artificial intelligence (AI) platform for collaborative management of cataracts involving multilevel clinical scenarios and explored an AI-based medical referral pattern to improve collaborative efficiency and resource coverage. Methods: The training and validation datasets were derived from the Chinese Medical Alliance for Artificial Intelligence, covering multilevel healthcare facilities and capture modes. The datasets were labelled using a three step strategy: (1)capture mode recognition; (2) cataract diagnosis as a normal lens, cataract or a postoperative eye and (3) detection of referable cataracts with respect to aetiology and severity. Moreover, we integrated the cataract AI agent with a real-world multilevel referral pattern involving self-monitoring at home, primary healthcare and specialised hospital services. Results: The universal AI platform and multilevel collaborative pattern showed robust diagnostic performance in three-step tasks: (1) capture mode recognition (area under the curve (AUC) 99.28%–99.71%), (2) cataract diagnosis (normal lens, cataract or postoperative eye with AUCs of 99.82%, 99.96% and 99.93% for mydriatic-slit lamp mode and AUCs >99% for other capture modes) and (3)detection of referable cataracts (AUCs >91% in all tests). In the real-world tertiary referral pattern, the agent suggested 30.3%  of people be ’referred’, substantially increasing the ophthalmologist-to-population service ratio by 10.2-fold compared with the traditional pattern. Conclusions: The universal AI platform and multilevel collaborative pattern showed robust diagnostic performance and effective service for cataracts. The context of our AI-based medical referral pattern will be extended to other common disease conditions and resource-intensive situations.

Review Article

The status quo and advances in categorization of congenital cataract

:56-66
 

Congenital cataract (CC) is one of the most common causes of pediatric visual impairment. As our understanding of CC's etiology, clinical manifestations, and pathogenic genes deepens,various CC categorization systems based on diferent classifcation criteria have been proposed. Regrettably, the application of the CC category in clinical practice and scientifc research is limited. It is challenging to obtain preciseinformation that could guide the timely treatment decision-making for pediatric cataract patients or predict their prognosis from a specific CC classification. This review aims to discuss the statusquo of CC categorization systems and the potential directions for future research in this field, focusingon categorization principles and scientific application in clinical practice. Additionally, it aims to propose the potential directions for future research in this domain.

BJO专栏

Predicting the risk of glaucoma-related adverse events following secondary intraocular lens implantation in paediatric eyes: a 3-year study

:234-245
 
Aims: To establish and evaluate predictive models for glaucoma-related adverse events (GRAEs) following secondary intraocular lens (IOL) implantation in paediatric eyes. Methods: 205 children (356 aphakic eyes) receiving secondary IOL implantation at Zhongshan Ophthalmic Center with a 3-year follow-up were enrolled. Cox proportional hazard model was used to identify predictors of GRAEs and developed nomograms. Model performance was evaluated with time-dependent receiver operating characteristic (ROC) curves, decision curve analysis, Kaplan-Meier curves and validated internally through C-statistics and calibration plot of the bootstrap samples. Results: Older age at secondary IOL implantation (HR=1.5, 95% CI: 1.03 to 2.19), transient intraocular hypertension (HR=9.06, 95% CI: 2.97 to  27.67) and ciliary sulcus implantation (HR=14.55, 95% CI: 2.11 to 100.57) were identified as risk factors for GRAEs (all p<0.05). Two nomograms were established. At postoperatively 1, 2 and 3 years, model 1 achieved area under the ROC curves (AUCs) of 0.747 (95% CI: 0.776 to 0.935), 0.765 (95% CI: 0.804 to 0.936) and 0.748 (95% CI: 0.736 to 0.918), and the AUCs of model 2 were 0.881 (95% CI: 0.836 to 0.926), 0.895 (95% CI: 0.852 to 0.938) and 0.848 (95% CI: 0.752 to 0.945). Both models demonstrated fine clinical net benefit and performance in the interval validation. The Kaplan-Meier curves showing two distinct risk groups were well discriminated and robust in both models. An online risk calculator was constructed. Conclusions: Two nomograms could sensitively and accurately identify children at high risk of GRAEs after secondary IOL implantation to help early identification and timely intervention.

Role of Omics Approaches in the Study of Pediatric Cataract

:-
 
Pediatric cataract is a primary blinding eye disease in children worldwide, imposing a substantial financial burden on families and society. With extensive phenotypic heterogeneity, underlying mechanisms of pediatric cataract remain unclear, which restrict more precise and effective treatment of the disease. The emergence of omics technologies has provided powerful tools for exploring the pathogenesis of pediatric cataract. By delineating expression profiles of pediatric cataract across various molecular levels, omics approaches enrich our understanding of the disease's etiological mechanisms, facilitate the identification of novel biomarkers and key pathways, and offer new insights to researchers for the innovative strategies in disease diagnosis and targeted treatments. In this review, we summarize the application of omics approaches in clinical and basic research of pediatric cataract in the past decade, including genomics, transcriptomics, proteomics, and metabolomics. Moreover, current challenges and future perspectives of omics analyses in pediatric cataract studies are discussed.

tester

:-
 
1. Scope of application (a) When you register for this website account, you provide personal registration information according to the requirements of the website; (b) The information on your browser and computer that this website automatically receives and records when you use the web services of this website or visit the Web pages of this platform, including but not limited to your IP address, the type of browser, the language used, the date and time of access, software and hardware characteristics information and the web records you require; (c) Personal data of users obtained by this website from business partners through lawful means. (d) Users of this website are strictly prohibited from Posting objectionable information, such as nudity, pornography and profane content. We will review the content posted and disable all permissions of the user once found to be objectionable. 2. Use of information (a) This website will not provide, sell, rent, share or trade your personal login information to any unrelated third party. If we store repairs or upgrades, we will send a push message to notify you in advance, please allow this page message notification in advance. (b) This website also does not allow any third party to collect, edit, sell or distribute your personal information by any means. If any user of this website engages in the above activities, once found, this website has the right to immediately terminate the service agreement with the user. (c) For the purpose of serving users, this website may provide you with information of interest to you through the use of your personal information, including but not limited to sending you information about products and services, or sharing information with partners of this website so that they can send you information about their products and services (the latter requires your prior consent) 3. Information disclosure Under the following circumstances, this website will disclose your personal information in whole or in part according to your personal wishes or the provisions of the law: (a) We will not disclose to third parties without your prior consent; (b) Share your personal information with third parties in order to provide the products and services you have requested; (c) disclose to third parties or administrative or judicial bodies in accordance with the relevant provisions of the law or at the request of administrative or judicial bodies; (d) If you have violated the relevant laws and regulations of China or this web service agreement or relevant rules, need to disclose to a third party; (e) If you are a qualified IP complainant and have filed a complaint, disclose it to the respondent at the request of the Respondent so that the parties can deal with possible disputes over rights; 4. Information storage and exchangeThe information and data collected about you on this website will be saved on the server of this website and (or) its affiliated companies, and such information and data may be sent to your country, region or overseas where the information and data collected on this website are located and will be accessed, stored and displayed overseas. 5. Use of cookies (a) If you do not refuse to accept cookies, the website will set up or access cookies on your computer so that you can log in to or use the website platform services or features that rely on cookies. The use of cookies on this website can provide you with more thoughtful personalized services, including promotional services. (b) You have the right to choose to accept or reject cookies. You can refuse to accept cookies by modifying your browser Settings. However, if you choose not to accept cookies, you may not be able to log in to or use the Web services or features that rely on cookies. (c) This Policy applies to information obtained through cookies on this website. 6. Changes to this Privacy Policy
Original Article

Changes in crystalline lens parameters during accommodation evaluated using swept source anterior segment optical coherence tomography

:44-55
 

Backgrounds: To assess changes in anterior segment biometry during accommodation using a swept source anterior segment optical coherence tomography (SS-OCT).

Methods: One hundred-forty participants were consecutively recruited in the current study. Each participant underwent SS-OCT scanning at 0 and -3 diopter (D) accommodative stress after refractive compensation, and ocular parameters including anterior chamber depth (ACD), anterior and posterior lens curvature, lens thickness (LT) and lens diameter were recorded. Anterior segment length (ASL) was defined as ACD plus LT. Lens central point (LCP) was defined as ACD plus half of the LT. The accommodative response was calculated as changes in total optical power during accommodation.

Results: Compared to non-accommodative status, ACD (2.952±0.402 vs. 2.904±0.382 mm, P<0.001), anterior (10.771±1.801 vs. 10.086±1.571 mm, P<0.001) and posterior lens curvature (5.894±0.435 vs. 5.767±0.420 mm, P<0.001), lens diameter (9.829±0.338 vs. 9.695±0.358 mm, P<0.001) and LCP (4.925±0.274 vs. 4.900±0.259 mm, P=0.010) tended to decreased and LT thickened (9.829±0.338 vs. 9.695±0.358 mm, P<0.001), while ASL (6.903±0.279 vs. 6.898±0.268 mm, P=0.568) did not change significantly during accommodation. Younger age (β=0.029, 95% CI: 0.020 to 0.038, P<0.001) and larger anterior lens curvature (β= -0.071, 95% CI: -0.138 to -0.003, P=0.040) were associated with accommodation induced greater steeping amplitude of anterior lens curvature. The optical eye power at 0 and -3 D accommodative stress was 62.486±2.284 and 63.274±2.290 D, respectively (P<0.001). Age was an independent factor of accommodative response (β= -0.027, 95% CI: -0.038 to -0.016, P<0.001).

Conclusions: During -3 D accommodative stress, the anterior and posterior lens curvature steepened, followed by thickened LT, fronted LCP and shallowed ACD. The accommodative response of -3 D stimulus is age-dependent.

Original Article

Changes in corneal curvature and aberrations after cataract surgery

:67-74
 

Background: Surgically induced astigmatism (SIA) and corneal high-order aberrations (HOAs) are the two main causes of poor visual quality after cataract surgery. Changes in the parameters of corneal HOAs after cataract surgery and their effects on and relationships with changes in corneal curvature have not yet been reported. This study aimed to explore changes in anterior, posterior and total corneal curvature, astigmatism and HOAs after microincision cataract surgery.

Methods: Sixty-one age-related cataract patients (61 eyes) were included in this prospective study. The total, anterior and posterior corneal astigmatism and corneal HOAs were analyzed by anterior segment optical coherence tomography (AS-OCT) and iTrace before, one day, one week and three months after 2.2 mm temporal microincision coaxial phacoemulsification to evaluate the changes in anterior, posterior and total corneal curvature, astigmatism and corneal HOAs.

Results: The mean J0 and J45 values of anterior, posterior and total corneal curvature obtained by AS-OCT showed no statistically significant difference between preoperatively and any postoperative follow-up. SIA occurred on the anterior, posterior and total corneal surfaces and showed no statistically significant difference at any postoperative follow-up. No significant changes in 3rd-order oblique trefoil, vertical coma or 4th-order spherical aberrations were observed after surgery except for a significant increase in horizontal coma at postoperative day 1 (POD1).

Conclusions: There were no significant changes in corneal curvature after 2.2 mm temporal microincision coaxial phacoemulsification, and the corneal HOAs were not changed significantly except for the increase in horizontal coma at POD1, which may be one of the main reasons of poor visual quality at POD1 in some cataract patients who have good uncorrected or corrected distance vision.

Original Article

Changes in crystalline lens parameters during accommodation evaluated using swept source anterior segment optical coherence tomography

:-
 

Backgrounds: To assess changes in anterior segment biometry during accommodation using a swept source anterior segment optical coherence tomography (SS-OCT).

Methods: One hundred-forty participants were consecutively recruited in the current study. Each participant underwent SS-OCT scanning at 0 and ?3 diopter (D) accommodative stress after refractive compensation, and ocular parameters including anterior chamber depth (ACD), anterior and posterior lens curvature, lens thickness (LT) and lens diameter were recorded. Anterior segment length (ASL) was defined as ACD plus LT. Lens central point (LCP) was defined as ACD plus half of the LT. The accommodative response was calculated as changes in total optical power during accommodation.

Results: Compared to non-accommodative status, ACD (2.952±0.402 vs. 2.904±0.382 mm, P<0.001), anterior (10.771±1.801 vs. 10.086±1.571 mm, P<0.001) and posterior lens curvature (5.894±0.435 vs. 5.767±0.420 mm, P<0.001), lens diameter (9.829±0.338 vs. 9.695±0.358 mm, P<0.001) and LCP (4.925±0.274 vs. 4.900±0.259 mm, P=0.010) tended to decreased and LT thickened (9.829±0.338 vs. 9.695±0.358 mm, P<0.001), while ASL (6.903±0.279 vs. 6.898±0.268 mm, P=0.568) did not change significantly during accommodation. Younger age (β=0.029, 95% CI: 0.020 to 0.038, P<0.001) and larger anterior lens curvature (β=?0.071, 95% CI: ?0.138 to ?0.003, P=0.040) were associated with accommodation induced greater steeping amplitude of anterior lens curvature. The optical eye power at 0 and ?3 D accommodative stress was 62.486±2.284 and 63.274±2.290 D, respectively (P<0.001). Age was an independent factor of accommodative response (β=?0.027, 95% CI: ?0.038 to ?0.016, P<0.001).

Conclusions: During ?3 D accommodative stress, the anterior and posterior lens curvature steepened, followed by thickened LT, fronted LCP and shallowed ACD. The accommodative response of ?3 D stimulus is age-dependent.

Original Article

Changes in corneal curvature and aberrations after cataract surgery

:-
 

Background: Surgically induced astigmatism (SIA) and corneal high-order aberrations (HOAs) are the two main causes of poor visual quality after cataract surgery. Changes in the parameters of corneal HOAs after cataract surgery and their effects on and relationships with changes in corneal curvature have not yet been reported. This study aimed to explore changes in anterior, posterior and total corneal curvature, astigmatism and HOAs after microincision cataract surgery.

Methods: Sixty-one age-related cataract patients (61 eyes) were included in this prospective study. The total, anterior and posterior corneal astigmatism and corneal HOAs were analyzed by anterior segment optical coherence tomography (AS-OCT) and iTrace before, one day, one week and three months after 2.2 mm temporal microincision coaxial phacoemulsification to evaluate the changes in anterior, posterior and total corneal curvature, astigmatism and corneal HOAs.

Results: The mean J0 and J45 values of anterior, posterior and total corneal curvature obtained by AS-OCT showed no statistically significant difference between preoperatively and any postoperative follow-up. SIA occurred on the anterior, posterior and total corneal surfaces and showed no statistically significant difference at any postoperative follow-up. No significant changes in 3rd-order oblique trefoil, vertical coma or 4th-order spherical aberrations were observed after surgery except for a significant increase in horizontal coma at postoperative day 1 (POD1).

Conclusions: There were no significant changes in corneal curvature after 2.2 mm temporal microincision coaxial phacoemulsification, and the corneal HOAs were not changed significantly except for the increase in horizontal coma at POD1, which may be one of the main reasons of poor visual quality at POD1 in some cataract patients who have good uncorrected or corrected distance vision.

其他期刊
  • 眼科学报

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
  • Eye Science

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
出版者信息