目的:总结大批量白内障扶贫手术的护理安全管理经验。方法:回顾性分析2013至2016年中山大学中山眼科中心医疗队完成大批量白内障扶贫手术的经验、针对下乡扶贫的特殊环境、患者入院时间短、手术量大、接台手术多以及患者自我管理能力差等情况,分析其安全隐患,并在护理过程中采取相应的安全措施。术前充分评估和准备,对患者进行健康指导;术中对手术环境规范管理;指导加强术后患者的自我管理。结果:8批次共1 064例白内障摘除联合人工晶体植入术顺利完成,无1例发生术后感染。结论:建立大批量白内障扶贫手术护理安全质量管理的规范流程是扶贫工作的重要环节,做好术前的评估和准备工作,落实患者的健康教育及术后患者自我管理指导,才能确保手术顺利进行。
To assess the safety of mass volume of cataract surgery and to identify the possible factors with enhanced patients’ safety. Methods: This is a retrospective case series. Clinical data of patients undergoing charity cataract extraction by surgeons from Zhongshan Ophthalmic Center between 2013 and 2016 was reviewed. The following factors were analyzed: safety management peri-operatively, educational interventions, intraoperative sterilization, and self-management after operations. Results: A total of 1064 patients (8 sessions) underwent cataract extraction and intraocular lens implantation. No evidence of endophthalmitis in any cases was observed. Conclusion: Establishment of standardized operation procedures for nursing safety management is essential for safety of mass volume of charity cataract surgery in China. Adequate assessment and peri-operative endeavor, educational interventions, nurse guided self-management should be empowered to enhance patients’ safety.
目的:观察后房型有晶体眼人工晶体(implantable collamer lens,ICL)V4c植入术后2年的有效性、安全性和稳定性,评估ICL V4c矫正屈光不正的中远期临床疗效。方法:回顾性病例研究。收集在河北省沧州市中心医院眼一科行ICL V4c手术治疗的屈光不正患者,观察并记录术前至术后2年的裸眼视力、最佳矫正视力、屈光状态、对比敏感度、高阶像差、眼压、人工晶体拱高、角膜内皮细胞计数、不良反应、主观视觉质量等临床资料,进行统计学分析。结果:完成随访的96例术眼,术后2年的平均裸眼视力(LogMAR)为0.021±0.065,平均最佳矫正视力(LogMAR)为0.002±0.041,优于术前最佳矫正视力,有效性指数为1.05,安全性指数为1.09,等效球镜数值稳定,对比敏感度提升,高阶像差有所增加,但主观视觉质量良好,眼压基本稳定,内皮细胞丢失率为1.6%,平均拱高为(549.6±50.0) μm,随访期间未发现眼内感染、继发性青光眼、晶状体混浊、黄斑水肿、视网膜脱离等并发症。结论:ICL V4c植入术矫正屈光不正具有良好的中远期临床效果。
Abstract Objective: To assess the medium-long term efficacy, safety and stability of a newly developed posterior chamber phakic intraocular lens (model V4c Visian Implantable Collamer Lens) to correct refractive errors. Methods: Retrospective case series. This study evaluated eyes that had implantation of ICL V4c to correct ametropia for at least two years. Uncorrected and corrected distance visual acuities, refraction, contrast sensitivity, high-order aberration, quality of life, intraocular pressure, endothelial cell density, pIOL vault, and adverse events were evaluated to assess the efficacy, safety and stability of V4c. Results: The study comprised 96 eyes of 50 patients. At 2 years postoperatively, the mean uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were 0.021±0.065 logMAR and 0.002±0.041 logMAR, which were better than preoperative CDVA. The efficacy and safety indices were 1.05 and 1.09, respectively. The spherical equivalent was stable withimproved contrast sensitivity and increased high-order aberrations, but the subjective visual quality was well. The IOP remained stable over time. The mean vault was (549.6±50.0) μm and the mean endothelial cell loss was 1.6%. No eye developed intraocular infection, secondary glaucoma, lens opacity, macular edema or retinal detachment. Conclusion: The good medium-long term outcomes support the use of ICL V4c for the correction of myopia.
[摘 要] 目的:研究准分子激光原位角膜磨镶术(laser in situkeratomileusis,LASIK)前后角膜滞后量(corneal hysteresis,CH)和角膜阻力因子(corneal resistance factor,CRF)变化量,对其相关因素进行多元线性回归分析。方法:前瞻性研究。纳入行LASIK手术的近视眼及近视散光患者70眼(38例),术前与术后6个月各项参数分别由眼反应分析仪(ocular response analyzer,ORA)、非接触眼压仪、超声角膜测厚仪及Pentacam眼前节分析仪测量。分析LASIK手术前后△CH,△CRF与术前、手术设计等参数的相关性,并对相关参数进行多元线性回归分析。结果:手术前后CH分别为(10.05±1.36),(8.15±0.90) mmHg(1 mmHg=0.133 kPa),CRF分别为(9.91±1.38),(6.92±0.88) mmHg,差异均有统计学意义(P<0.01);△CH与△CRF分别为(1.90±1.15),(2.99±1.23) mmHg。△CH与术前CH,CRF,眼压(intraocular pressure,IOP),预计切削深度(ablative depth,AD)以及AD/CCT呈正相关;△CRF与术前CH,CRF,IOP,AD,AD/CCT,术前等值球镜(spherical equivalent,SE)以及预计 基质床厚度(residual stromal bed’s thickness,RSBT)有相关性。采用多元线性回归对LASIK手术前后△CH,△CRF与术前、手术设计等各相关参数进行分析,回归方程为:△CH=?6.182+0.658CH术前+8.421AD/CCT (R2=0.639,P<0.01),△CRF=?0.007+0.725CRF术前?0.014RSBT (R2=0.689,P<0.01)。结论:LASIK术前后CH与预计AD和角膜厚度比值密切相关,CRF变化量与预计角膜RSBT密切相关,在设计手术时应慎重考虑预计AD与预计RSBT。
Abstract Objective: To discuss the change of corneal hysteresis and corneal resistance factor before and after laser in situkeratomileusis (LASIK), and to analyze their related factors by multivariate linear regression. Methods: In this prospective study, 70 eyes (38 patients) with myopia and myopic astigmatism undergoing LASIK were included. Related factors were measured preoperatively and at 6 months postoperatively by ocular response analyzer, noncontact tonometer (NCT), ultrasonic pachymeter, and Pentacam system. The correlation was analyzed between △CH, △CRF and preoperative and operative design’s parameters, and correlative factors analyze. △CH and △CRF were analyzed by the multiple linear regression. Results: CH before and after LASIK were (10.05±1.36) and (8.15±0.90) mmHg, and CRF before andafter LASIK were (9.91±1.38) and (6.92±0.88) mmHg. There was significant difference between preoperative and postoperative CH and CRF (P<0.01). △CH and △CRF were (1.90±1.15) and (2.99±1.23) mmHg. Preoperative CH, CRF, intraocular pressure (IOP), ablative depth (AD) and AD/CCT were positive correlated with △CH. Preoperative CH, CRF, IOP, AD, AD/CCT, preoperative spherical equivalent (SE) and predicted residual stromal bed’s thickness (RSBT) were correlated with △CRF. The regression equation of △CH and △CRF and influencing factors were △CH =?6.182 + 0.658CHpreoperative + 8.421AD/CCT (R2=0.639, P<0.01), △CRF =?0.007 + 0.725CRFpreoperative ? 0.014RSBT (R2=0.689, P<0.01). Conclusion: The change of CH before and after LASIK is correlative with AD/CCT. The change of CRF before and after LASIK is correlative with predicted residual stromal bed’s thickness. Ablative depth and predicted residual stromal bed’s thickness should be considered carefully during the surgical design.
目的:观察健康中老年人群中心凹视觉敏感度阈值(foveal threshold,FT)及光相干断层扫描血管成像(optical coherence tomography angiography,OCTA)的双眼对称性。方法:横断面观察性研究。纳入33例66眼,测量并比较眼灌注压(ocular perfusion pressure,OPP),FT,黄斑区3 mm × 3 mm范围内中心凹无血管区面积(non-flow area,NFA),浅层视网膜血管密度(superior vessel density,SVD)和深层视网膜血管密度(deep vessel density,DVD)的双眼对称性;分析各指标双眼差值、均值及其比值与年龄、性别的相关性。结果:配对样本t检验结果显示除FT(t=?2.118,P=0.042)外,左右眼OPP,NFA,SVD和DVD差异均无统计学意义(P>0.05);Pearson相关性分析和同类相关系数(intra-class correlation coefficient,ICC)检验结果显示5项指标左右眼测量值相关强度由强到弱为OPP>FT>NFA>DVD>SVD;Bland-Altman分析结果提示5项指标双眼间一致性良好。5项指标的双眼对称性不随性别、年龄改变。结论:健康中老年人群FT、黄斑区NFA,SVD及DVD的测量值具有双眼对称性。
Objective: To observe the interocular symmetry of foveal threshold (FT) and optical coherence tomography angiography (OCTA) parameters in healthy middle-aged and elderly subjects. Methods: Cross-sectional observational study. Sixty-six eyes from thirty-three subjects were enrolled to compare binocular ocular perfusion pressure (OPP), FT, non-flow area (NFA), superior vessel density (SVD) and deep vessel density (DVD) in a 3 mm × 3 mm OCTA scan of macula. The interocular symmetry of all the parameters was analyzed; the correlations of the differences (△), mean value (m) and the ratio of all the parameters with age and gender were analyzed. Results: There was no significant interocular difference revealed by paired-samples t-tests in all the parameters (P>0.05) except FT (t=?2.118, P=0.042), while the rank of Pearson’s correlation index and intraclass correlation coefficient (ICC) from strong to weak was OPP > FT > NFA > DVD > SVD. The interocular symmetry of all the parameters was proved to be good with Bland-Altman plots, and it changed little with the variations of age and gender. Conclusion: Interocular symmetries of FT and OCTA parameters are observed in healthy middle-aged and elderly subjects.