Cornea and Anterior segment

AB083. Intraocular lens biocompatibility: a novel, objective approach

:-
 

Background: Understanding factors that contribute to posterior capsular opacification (PCO) development is a significant public concern as treatment can lead to complications. In order to prevent PCO, a better understanding of intraocular lens (IOL) characteristics, including design and material, and patient interaction is required. Herein, we performed a retrospective multivariable analysis to determine which factors (IOL and patient based) were least likely to result in PCO.

Methods: One hundred eighty post-mortem eyes with implanted IOLs were collected from the Minnesota Eye Bank, along with clinical history, including date of cataract surgery and IOL model number. The capsular bag (CB) with the IOL implant was removed from all eyes to obtain digital images. PCO outcome was quantified on CB images using an objective, automated custom image analyzer (Medical Parachute Automated Detector Opacification Software). The software measured intensity and area of the opacification within the IOL optic edge, intra-optic edge (IOE = intensity/area), and in Soemmering’s ring (SR = intensity/area). Epidemiologic analysis assessed which IOL characteristics and patient-related factors correlated with PCO. IOL factors included material, edge design, lens filter, company, IOL model, decentration and time from cataract surgery to death. Patient factors included sex, age and diabetes, among others.

Results: Multivariate analyses showed non-diabetic patients had less PCO (P=0.05). Individuals 50–80 years old compared to 80+ had lower SR PCO (P=0.04). Non-blue light filter IOLs had lower SR and IOE PCO compared to filter IOLs (P=0.03, 0.001). Square and frosted optic edge design had lower SR and IOE PCO rates compared to OptiEdge and round optic edge design (P=0.002, 0.02). The IOL model that had the least PCO was the ZA9003 model, but this was only significant for SR and not IOE PCO (P=0.04). Adjusting for patient-factors, IOL lens model was no longer a confounding factor for PCO. Patients with an IOL implanted for <7 years had lower SR PCO, whereas lower IOE PCO was only seen in implants <4 years old (P=0.0001, 0.04).

Conclusions: In order to generate a lens that does not develop PCO, it is critical to understand the IOL- and patient-related factors that lead to PCO development. Based on our data, the most susceptible patients are elderly and diabetic, and it may be preferable to implant a square and frosted edge lens without blue-light filtering in this cohort.

Retina and Posterior Segment

AB016. A standardized approach to correlating OCT images to histopathology using paraffin embedded specimens: clarification of the ellipsoid zone and new opportunities

:-
 

Background: The aim of this project is to develop a new standardized and cost-efficient method to compare optical coherence tomography (OCT) scans to their corresponding paraffin embedded histopathology sections in post-mortem eyes. This correlation will clarify the interpretation of OCT images, and it will also enable direct immunohistochemical characterization of features observed on OCT.

Methods: Study design: donor eyes were obtained from two separate eye banks. In order to minimize post-mortem change like retinal detachment and vitreous opacification, the eyes were fixed in a previously tested fixative solution. Time between death and fixation has been kept under 6 hours. Methods: Using a customized imaging device, nine post-mortem eyes were imaged with a SD-OCT machine. Subsequently, an 8mm trephine was used to isolate a portion of the posterior pole including the macular area and the optic nerve head for histopathological analysis. Paraffin embedded cross sections of the retina were obtained and visually compared to each OCT image (b-scans).

Results: To facilitate the correlation of OCT images to their histopathological sections, three principle aspects were controlled during tissue processing: rotation, tilt and location. Using markings as well as anatomical landmarks, serial histopathological sections in an orientation comparable to OCT b-scans were obtained, thereby facilitating image pairing.

Conclusions: Compared to other well-established methods using resin and electron microscopy, our standardized Methods allowed us to successfully compare OCT b-scans to serial retinal cross sections of a wider macular area at a lower cost. Our novel approach allows us to translate features observed on OCT images into well-established histopathological images, providing the clinician with additional tools to obtain difficult diagnoses with more confidence.

其他期刊
  • 眼科学报

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
  • Eye Science

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
出版者信息