医学教育

“实验室技能培训课程”课程思政的探索与实践

Exploration and practice on integrating ideological and political education throughout laboratory skills training curriculum

:-
 
将课程思政理念融入专业课程是落实立德树人根本任务和全面推进课程育人的重要途径。本文根据课程思政的内涵要求和发展实际,结合实验室技能培训课程特点,从知识点、人与社会、故事、案例辨析、实验操作5个方面进行思政探索和实践。通过优化教学设计、创新教学方法和丰富教学内容,切实将社会主义核心价值观教育贯穿专业课教育全过程,为眼科学及分子医学专业课相关课程的思政教学和高质量人才培养提供了有价值的参考。
Integrating ideological and political concepts of the curriculum into the professional curricula is an important way to implement the fundamental task of cultivating people with morality and comprehensively promote the education of people through the curriculum. Based on the connotation requirements and actual development of the integration of ideological and political education throughout curriculum, considering the features of laboratory skills training courses, this paper explores ideological and political education in 5 aspects. The 5 aspects include knowledge points, humans and society, stories, case analysis, and experimental operation. By optimizing teaching design, innovating teaching methods, and enriching teaching contents, the education of socialist core values should be effectively carried out throughout the whole process of professional course education, which provides a valuable reference for the ideological and political teaching in ophthalmology and molecular medicine related courses and for the cultivation of high-quality talents.
论著

近视与糖尿病人群黄斑区节细胞-内丛状层厚度纵向变化的关联研究

Association of myopia with the macular ganglion cell layer and inner plexiform layer in diabetic patients: A longitudinal study

:-
 
目的:探讨无糖尿病性视网膜病变(diabetic retinopathy,DR)的糖尿病人群中,糖尿病与近视对黄斑区节细胞-内丛状层(ganglion cell layer and inner plexiform layer,GCIPL)厚度纵向变化的影响。方法:纳入广州糖尿病眼病研究中1 165名基线无视网膜病变的糖尿病和正常对照者,纵向随访2年。根据是否存在近视[等效球镜(spherical equivalent,SE)≤-3 屈光度(diopter,D)]和糖尿病分为健康组(n =508)、糖尿病组(n =525)及糖尿病合并近视组(n =132)。扫频光学相干断层成像(swept source-optical coherence tomography,SS-OCT)技术测量并比较三组间GCIPL厚度的变化,以确定糖尿病和近视的影响,三组间差异使用协方差分析,采用线性混合模型分析评估GCIPL厚度与相关因素的关系。结果:对照组的SE为(1.07±1.06) D,糖尿病组为(1.02±1.00) D,糖尿病合并近视组为(-5.36±2.30D),组间差异有统计学意义(P<0.001)。对照组基线GCIPL厚度为(71.1±0.3) μm,糖尿病组为(74.4±0.2) μm,糖尿病合并近视组为(71.7±0.5) μm。在2年随访过程中,对照组GCIPL厚度下降-0.10(95%CI:0.05~-2.03) μm/年,糖尿病组GCIPL厚度下降的速度为对照组的12倍[-1.21(95%CI:0.05~?24.04) μm/年,P<0.001],糖尿病合并近视组GCIPL厚度下降的速度为对照组的22倍[-2.17(95%CI:0.10~-21.63) μm/年,P<0.001]。结论:近视是无DR的糖尿病患者中GCIPL加速变薄的危险因素,糖尿病和近视GCIPL损伤中可能存在协同作用。
Objective: To investigate the association between myopia and ganglion cell layer and inner plexiform layer(GCIPL) in diabetic population without diabetic retinopathy (DR). Methods: In this Guangzhou Diabetic Eyestudy, a total of 1165 patients aged 30–80 years were recruited followed up longitudinally for 2 years. According tothe presence or absence of myopia [spherical equivalence (SE)≤-3 diopter (D)] and diabetics, the patients weredivided into a healthy group (n=508), a diabetes mellitus group (n=525), and a diabetes mellitus + myopia group(n=132). GCIPL was measured via swept-source optical coherence tomography. Univariable and multivariablemixed models were used to show the association of GCIPL change and baseline parameters. Results: SE was(1.07±1.06) D in the healthy group, (1.02±1.00) D in the diabetes mellitus group and (-5.36±2.30) D in thediabetes mellitus + myopia group (P<0.001). The baseline GCIPL thickness were (71.1±0.3), (74.4±0.2), and(71.7±0.5) μm, respectively. The slope of GCIPL thickness was ?0.10 (95% CI: 0.05 to -2.03) μm/year in the healthy group, which was 12 folds faster than those in the diabetes mellitus group [-1.21(95% CI: 0.05 to-24.04) μm/year, P<0.001] and 22 folds higher among those in diabetes mellitus + myopia group [-2.17 (95%CI: 0.10 to ?21.63) μm/year, P=0.009]. Conclusion: Both myopia and diabetes status accelerate macular ganglioncell layer and inner plexiform layer thinning in diabetic patients without diabetic retinopathy.
Editorial
Editorial
Original Article
Technical Note

Allogeneic sclera graft combined autologous conjunctival flap for repairing the emergent corneal perforation

Allogeneic sclera graft combined autologous conjunctival flap for repairing the emergent corneal perforation

:-
 

Abstract: To report a palliative and alternative surgical procedure, allogeneic sclera graft combined with autologous conjunctival flap (ASGACF), employing to repair the large emergent corneal perforation. The detail protocol of the surgical procedure was characterized and four representative cases were reviewed. An allogeneic sclera graft and recipient bed were prepared as the traditional penetrating keratoplasty (PK). And then sutured the sclera graft to the bed with 10-0 nylon suture and covered with a pedicled autologous conjunctival flap in half size. In the follow-up, the ASGACF repaired all of the corneal perforations and restored the integral walls of eyeballs, in spite of one who underwent a second surgery. This surgical procedure provided a palliative method to repair the large emergent corneal perforation while there is the lack of a corneal graft.

Abstract: To report a palliative and alternative surgical procedure, allogeneic sclera graft combined with autologous conjunctival flap (ASGACF), employing to repair the large emergent corneal perforation. The detail protocol of the surgical procedure was characterized and four representative cases were reviewed. An allogeneic sclera graft and recipient bed were prepared as the traditional penetrating keratoplasty (PK). And then sutured the sclera graft to the bed with 10-0 nylon suture and covered with a pedicled autologous conjunctival flap in half size. In the follow-up, the ASGACF repaired all of the corneal perforations and restored the integral walls of eyeballs, in spite of one who underwent a second surgery. This surgical procedure provided a palliative method to repair the large emergent corneal perforation while there is the lack of a corneal graft.

Editorial
Original Article

Supracapsular implantation with optic capture of posterior chamber intraocular lens in Chinese children with aphakic after traumatic cataract

Supracapsular implantation with optic capture of posterior chamber intraocular lens in Chinese children with aphakic after traumatic cataract

:-
 

Background: To assess the safety and efficacy of supracapsular implantation with optic capture of the posterior chamber intraocular lens in Chinese children with aphakic after traumatic cataract.

Methods: It was a retrospective case series study. Fifteen cases (15 eyes) Chinese children received supracapsular implantation with optic capture of the posterior chamber intraocular lens. Pre- and post-operative visual acuities were recorded. Intra- and post-operative complications were observed. The follow-up period ranged from 7 to 43 (28.7±7.2) months.

Results: Implantation of optic capture of the posterior chamber intraocular lens was successfully performed in 15 eyes. The best corrected visual acuity (BCVA) ranged from 0.3 to 1.0 (0.61±0.19). No optic axis opaque was found in 15 eyes with optic capture. The major complications of optic capture were iris posterior synechia and intraocular lens (IOL) precipitates. Intraocular dislocation was found in one case three weeks after the operation.

Conclusions: Supracapsular implantation with optic capture of the posterior chamber intraocular lens is safe and effective for the treatment of traumatic cataract in Chinese children.

Background: To assess the safety and efficacy of supracapsular implantation with optic capture of the posterior chamber intraocular lens in Chinese children with aphakic after traumatic cataract.

Methods: It was a retrospective case series study. Fifteen cases (15 eyes) Chinese children received supracapsular implantation with optic capture of the posterior chamber intraocular lens. Pre- and post-operative visual acuities were recorded. Intra- and post-operative complications were observed. The follow-up period ranged from 7 to 43 (28.7±7.2) months.

Results: Implantation of optic capture of the posterior chamber intraocular lens was successfully performed in 15 eyes. The best corrected visual acuity (BCVA) ranged from 0.3 to 1.0 (0.61±0.19). No optic axis opaque was found in 15 eyes with optic capture. The major complications of optic capture were iris posterior synechia and intraocular lens (IOL) precipitates. Intraocular dislocation was found in one case three weeks after the operation.

Conclusions: Supracapsular implantation with optic capture of the posterior chamber intraocular lens is safe and effective for the treatment of traumatic cataract in Chinese children.

Review Article
Review Article

How to screen diabetic retinopathy within communities

How to screen diabetic retinopathy within communities

:-
 

Abstract: Diabetic retinopathy (DR) remains a leading cause of irreversible vision loss in adult populations around the globe. Despite growing evidence of the effectiveness of routine assessments and early intervention, DR screening strategies are not widely implemented largely due to an inadequate availability of resources to cope with the growing burden of diabetes. Advances in technology in the field of DR screening are clearly warranted and the recent emergence of deep learning-based artificial intelligence (AI) grading of retinal pathology offers significant potential benefits including an increased efficiency, accessibility and affordability of screening programmes.

Abstract: Diabetic retinopathy (DR) remains a leading cause of irreversible vision loss in adult populations around the globe. Despite growing evidence of the effectiveness of routine assessments and early intervention, DR screening strategies are not widely implemented largely due to an inadequate availability of resources to cope with the growing burden of diabetes. Advances in technology in the field of DR screening are clearly warranted and the recent emergence of deep learning-based artificial intelligence (AI) grading of retinal pathology offers significant potential benefits including an increased efficiency, accessibility and affordability of screening programmes.

其他期刊
  • 眼科学报

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
  • Eye Science

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
推荐阅读
出版者信息