Review Article

Design and recent results of large-scale cohort epidemiology studies on refractive error in children in Shanghai

:-
 

Abstract: Between 2011 and 2013, two large-scale cohort epidemiology studies were launched in Shanghai: the SCALE study, which aimed to provide ocular public health services to cover the entire youth population in Shanghai, and the SCES, which was based on sample surveys and aimed to provide information on the prevalence and incidence of visual impairment and different types of refractive errors. A total of 910,245 children and adolescents were finally enrolled in the SCALE study; three possible methods for monitoring refractive error without mydriasis were tested, and the agreement between the refractive outcomes of three commonly used autorefractors were examined to ensure the accuracy of the results of the SCALE study. A total of 8,627 children were enrolled in the SCES, and the baseline prevalence of different refractive errors, different behaviors associated with 1 year myopic shifts, and the different patterns of 2-year myopia progression between internal migrant and local resident school children have been analyzed. In some subset samples of the SCALE study and the SCES, several refraction components such as choroidal thickness (ChT) and crystalline lens power were also measured, to further elucidate the relationships between the refraction components and myopia as well as the mechanism of myopia incidence and development. The three methods used in Shanghai to prevent and intervene with childhood myopia: increasing outdoor time, low concentration atropine, and use of orthokeratology lens are also addressed in this review.

Original Article

Objective electrophysiological contrast sensitivity with monofocal and multifocal intraocular lenses: a prospective clinical study

:-
 

Background: To compare objective electrophysiological contrast sensitivity function (CSF) in patients implanted with either multifocal intraocular lenses (MIOLs) or monofocal intraocular lenses (IOLs) by pattern reversal visual evoked potentials (prVEP) measurements.

Methods: Fourty-five cataract patients were randomly allocated to receive bilaterally: apodized diffractive-refractive Alcon Acrysof MIOL (A), full diffractive AMO Tecnis MIOL (B) or monofocal Alcon Acrysof IOL (C). Primary outcomes: 1-year differences in objective binocular CSF measured by prVEP with sinusoid grating stimuli of 6 decreasing contrast levels at 6 spatial frequencies. Secondary outcomes: psychophysical CSF measured with VCTS-6500, photopic uncorrected distance (UDVA), and mesopic and photopic uncorrected near and intermediate visual acuities (UNVA and UIVA respectively).

Results: Electrophysiological CSF curve had an inverted U-shaped morphology in all groups, with a biphasic pattern in Group B. Group A showed a lower CSF than group B at 4 and 8 cpd, and a lower value than group C at 8 cpd. Psychophysical CSF in group A exhibited a lower value at 12 cpd than group B. Mean photopic and mesopic UNVA and UIVA were worse in monofocal group compared to the multifocal groups. Mesopic UNVA and UIVA were better in group B.

Conclusions: Electrophysiological CSF behaves differently depending on the types of multifocal or monofocal IOLs. This may be related to the visual acuity under certain conditions or to IOL characteristics. This objective method might be a potential new tool to investigate on MIOL differences and on subjective device-related quality of vision.

Perspective

Degenerative myopia: mechanical theories revisited

:-
 

Abstract: The article discusses the early abandonment of mechanical theories about eye enlargement in degenerative myopia at the turn of the 20th century. At that time, the number of theories about myopia grew unrestricted, but with scant support from the experimental field. The mechanical theories vanished as a new wave of metabolism-based theories appeared, propelled by the huge advances in molecular biology. Modern techniques allow reconsidering those theories and to put them to test with higher confidence.

Cornea and Anterior segment

AB093. Ocular tissues bank for vision health research

:-
 

Background: This infrastructure delivers biological material necessary for several research projects to Vision Health Research Network investigators (VHRN).

Methods: Héma-Québec is the organism in charge obtaining consent and retrieving donor eyes for patient treatment or for research. In Quebec City, donor eyes are sent to the eye bank of the “Centre Universitaire d’Ophtalmologie” (CUO) of Saint-Sacrement hospital. Technicians at the eye bank evaluate the quality of the tissues. Those unfit for graft are transferred to the infrastructure where the coordinator encodes samples prior to their distribution.

Results: Between 2013 and 2017, 27 fundamental investigators, clinical investigators and collaborators supported by 60 students, trainees and laboratory assistants used this infrastructure to move forward their projects. Since 2013, results from those projects generated 21 scientific publications and 232 presentations. The infrastructure helped VHRN investigators obtain near 4 million dollars in grants from many organisms (CIHR, NSERC, Foundations, etc.). These grants allowed recruitment and formation of highly qualified personnel. Last year (April 2016 to March 2017), 189 corneas and 23 eyes transited through the infrastructure.

Conclusions: This infrastructure is available for all investigators that are members of the VHRN. Many original projects have been elaborated thanks to the human ocular tissues provided by this infrastructure. These projects will advance our knowledge in vision health. A better understanding of eye functions will lead to new treatments for eye diseases.

Cornea and Anterior segment

AB092. Database for the anatomopathological, functional and surgical characterization of the cornea

:-
 

Background: The purpose of this infrastructure is to provide to the Network researchers a database and diverse related tools for the anatomical and functional analysis of the normal, pathological and surgical cornea.

Methods: This database is composed of normal and pathological individuals, totaling more than 36,000 patients. It includes anatomical and functional imaging data, physiological optics data, psychometric and clinical data (medical history, surgical parameters, acuteness, etc.). Various corneal topography tools were added, giving the database a unique character: tools for analyzing individual maps, average map tools for the study and comparison of populations, 3D modeling and visualization tools, statistical tools, etc. There are also screening tools for detecting various corneal conditions (LASIK, PRK, RK, keratoconus) and for secure data exchange between colleagues.

Results: Several studies were made in recent years thanks to this common infrastructure. For example, this database has provided important information regarding the evolution of the 3D shape of the normal cornea with age and ametropia and has confirmed the mirror symmetry of corneas for the right and the left eyes (enantiomorphism). The different stages of Fuchs’ dystrophy were also characterized to provide essential knowledge for surgery of the posterior layer of the cornea. Our database also allowed studying the anatomy of the wounds and the shape of the cornea before and after a transfixing transplant or an endothelial transplant (DSAEK and DSEK). The data on the characterization of experimentally transplanted corneas with corneal equivalents generated by tissue engineering and the recent addition of clinical data on the replacement of a diseased cornea with a synthetic corneal equivalent (keratoprosthesis) also resulted in several publications. More recently, the database has allowed to develop innovative algorithms to determine the optimal shape of an implant according to the clinical parameters of the recipient. On the other hand, we also demonstrated that the 3D shape of the cornea can be used as a biometric characteristic (such as fingerprints) for identification of individuals for various applications ranging from forensics to secure border crossings. Consequently, a new multimodal database (cornea + iris + eventually retina) was created for the purpose of biometric identifications. This database provides a unique set of anatomical and functional tools for the analysis of the cornea. It is characterized by the scientific quality and large quantity of accumulated information on the cornea and the high-level tools to exploit its content.

Conclusions: The common infrastructure is easily accessible to all VHRN members on request. The database will also be accessible online in 2018 (see http://cvl.concordia.ca for more information).

Cornea and Anterior segment

AB089. Impact of WNK1 inhibition on corneal wound healing using a model of human tissue-engineered cornea

:-
 

Background: Because of its superficial anatomical localization, the cornea is particularly vulnerable to abrasive forces and various traumas, which can lead to significant visual impairments. Upon injury of the corneal epithelium, there are important changes that occur in the composition of the underlying extracellular matrix (ECM). Those changes are perceived by the integrins that recognize the ECM components as their ligand and activate different intracellular signalling pathways, ultimately leading to reepithelialisation and reorganization of the injured epithelium, both of which are necessary in order to restore the visual properties of the cornea. The goal of this study was to analyse the impact of the pharmacological inhibition of specific signal transduction mediators of integrin-dependant signalling pathways on corneal wound healing using both monolayers of hCECs and tissue-engineered human corneas (hTECs) as in vitro models.

Methods: hTECs were produced by the self-assembly approach and wounded with a 8-mm diameter biopsy punch. Total RNA and proteins were isolated from the wounded and unwounded hTECs to conduct gene profiling analyses and protein kinase arrays. The wounded tissues were then incubated with the WNK1 inhibitor WNK463 and wound healing was monitored over a period of 6 days. Control corneas were incubated with the vehicle alone (DMSO). The impact of WNK1 inhibition on hCECs monolayers was determined using a scratch wound assay.

Results: Gene profiling analyses and protein kinases arrays revealed important alterations in the expression and activity of several mediators from the integrin-dependent signalling pathways in response to the ECM changes taking place during corneal wound healing. Among these, WNK1 is considerably activated through phosphorylation during corneal wound healing. The pharmacological inhibition of WNK1 by WNK463 significantly reduced the dynamic of corneal wound closure in our hTECs and hCECs monolayers compared to their respective negative controls.

Conclusions: These results allowed the identification of WNK1 kinase as an important player for a proper healing of the cornea. Also, these results allowed for a better understanding of the cellular and molecular mechanisms involved in corneal wound healing and they may lead to the identification of new therapeutic targets in the field of corneal wounds.

Cornea and Anterior segment

AB087. Corneal phenotype of a Slc4a11 knockout murine model for congenital hereditary endothelial dystrophy

:-
 

Background: Congenital hereditary endothelial dystrophy (CHED) is characterized by blindness at birth or in early infancy resulting from bilateral corneal opacification, and is linked to mutation in the Slc4a11 gene. A Slc4a11 knockout (KO) mouse, generated by gene deletion (Vithana et al. Nat Genet 2006), was acquired in order to study this disease. To confirm the phenotype of this Slc4a11 KO mouse model as a function of age, using the wild type (WT) mouse as a control.

Methods: Genotyping was performed by PCR (REDExtract-N-AmpTM Tissue PCR Kit, Sigma-Aldrich, Oakville, ON). Slc4a11 WT and KO mice populations aged from 5 to 50 weeks were studied (n=5 animals per age group; 5-year age intervals). Slit lamp examination, anterior segment-ocular coherence tomography (OCT930SR; Thorlabs, Inc., Newton, NJ), corneal endothelial cell staining, and scanning (SEM) and transmission (TEM) electron microscopy were used to assess the morphological and cellular differences between the two groups. The expression of basolateral membrane transporter NaBC1 within the corneal endothelium was also assessed using immunohistochemistry.

Results: Diffuse and progressive corneal opacification was observed at the slit lamp in the Slc4a11 KO mice, starting at 10 weeks. The central corneal thickness (CCT) also increased progressively as a function of time. In comparison, Slc4a11 WT corneas remained clear over the entire study period. Early TEM results showed vacuole degeneration of the corneal endothelium in the 15-week KO mouse, which was not seen in the same age WT mouse.

Conclusions: The corneal phenotype of this Slc4a11 KO mouse is representative of the clinical manifestations of CHED in human subjects, confirming the usefulness of this model for studying pathophysiology and therapeutic alternatives for Slc4a11-associated corneal dystrophies.

Cornea and Anterior segment
Cornea and Anterior segment
Cornea and Anterior segment
其他期刊
  • 眼科学报

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
  • Eye Science

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
出版者信息