Original Article

Subjective refractions determined by Dyop? and LogMAR chart as fixation targets

:-
 

Background: Dyop® is a dynamic optotype with a rotating and segmented visual stimulus. It can be used for visual acuity and refractive error measurement. The objective of the study was to compare refractive error measurement using the Dyop® acuity and LogMAR E charts.

Methods: Fifty subjects aged 18 or above with aided visual acuity better than 6/12 were recruited. Refractive error was measured by subjective refraction methods using the Dyop® acuity chart and LogMAR E charts and the duration of measurement compared. Thibo’s notation was used to represent the refractive error obtained for analysis.

Results: There was no significant difference in terms of spherical equivalent (M) (P=0.96) or J0 (P=0.78) and J45 (P=0.51) components measured using the Dyop® acuity and LogMAR E charts. However, subjective refraction measurement was significantly faster using the Dyop® acuity chart (t=4.46, P<0.05), with an average measurement time of 419.90±91.17 versus 452.04±74.71 seconds using the LogMAR E chart.

Conclusions: Accuracy of refractive error measurement using a Dyop® chart was comparable with use of a LogMAR E chart. The dynamic optotype Dyop® could be considered as an alternative fixation target to be used in subjective refraction.

Review Article

Psychophysics in the ophthalmological practice—II. Contrast sensitivity

:-
 
Contrast is the differential luminance between one object and another. Contrast sensitivity (CS) quantifies the ability to detect this difference: estimating contrast threshold provides information about the quality of vision and helps diagnose and monitor eye diseases. High contrast visual acuity assessment is traditionally performed in the eye care practice, whereas the estimate of the discrimination of low contrast targets, an important complementary task for the perception of details, is far less employed. An example is driving when the contrast between vehicles, obstacles, pedestrians, and the background is reduced by fog. Many conditions can selectively degrade CS, while visual acuity remains intact. In addition to spatial CS, “temporal” CS is defined as the ability to discriminate luminance differences in the temporal domain, i.e., to discriminate information that reaches the visual cortex as a function of time. Likewise, temporal sensitivity of the visual system can be investigated in terms of critical fusion frequency (CFF), an indicator of the integrity of the magnocellular system that is responsible for the perception of transient stimulations. As a matter of fact, temporal resolution can be abnormal in neuro-ophthalmological clinical conditions. This paper aims at considering CS and its application to the clinical practice.
Review Article

Conjunctival flaps for the treatment of advanced ocular surface disease—looking back and beyond

:-
 
Conjunctival flaps have previously proven to be effective in preserving the globe for individuals with severe ocular surface disease. Infectious keratitis, neurotrophic keratitis, nontraumatic corneal melts, descemetoceles, perforations, and corneal burns are all indications for this procedure. The flaps promote nutrition, metabolism, structure, and vascularity, as well as reduce pain, irritation, inflammation, and infection. Furthermore, patients avoid the emotional and psychological repercussions of enucleation or evisceration, while requiring fewer postoperative medications and office visits. Currently, fewer flaps are performed due to the emergence of additional therapeutic techniques, such as serum tears, bandage lenses, corneal grafting, Oxervate, amniotic membrane, and umbilical cord grafting. However, despite newer conservative medical methods, conjunctival flaps have been demonstrated to be useful and advantageous. Moreover, future technologies and approaches for globe preservation and sight restoration after prior conjunctival flaps are anticipated. Herein, we review the history, advantages, and disadvantages of various surgical techniques: Gundersen’s bipedicle flap, partial limbal advancement flap, selective pedunculated conjunctival flap with or without Tenon’s capsule, and Mekonnen’s modified inferior palpebral-bulbar conjunctival flap. The surgical pearls and recommendations offered by the innovators are also reviewed, including restrictions and potential complications. Procedures for visual rehabilitation in selective cases after conjunctival flap are reviewed as well.
Original Article
Technical Note

Allogeneic sclera graft combined autologous conjunctival flap for repairing the emergent corneal perforation

:-
 

Abstract: To report a palliative and alternative surgical procedure, allogeneic sclera graft combined with autologous conjunctival flap (ASGACF), employing to repair the large emergent corneal perforation. The detail protocol of the surgical procedure was characterized and four representative cases were reviewed. An allogeneic sclera graft and recipient bed were prepared as the traditional penetrating keratoplasty (PK). And then sutured the sclera graft to the bed with 10-0 nylon suture and covered with a pedicled autologous conjunctival flap in half size. In the follow-up, the ASGACF repaired all of the corneal perforations and restored the integral walls of eyeballs, in spite of one who underwent a second surgery. This surgical procedure provided a palliative method to repair the large emergent corneal perforation while there is the lack of a corneal graft.

Review Article
Review Article

How to screen diabetic retinopathy within communities

:-
 

Abstract: Diabetic retinopathy (DR) remains a leading cause of irreversible vision loss in adult populations around the globe. Despite growing evidence of the effectiveness of routine assessments and early intervention, DR screening strategies are not widely implemented largely due to an inadequate availability of resources to cope with the growing burden of diabetes. Advances in technology in the field of DR screening are clearly warranted and the recent emergence of deep learning-based artificial intelligence (AI) grading of retinal pathology offers significant potential benefits including an increased efficiency, accessibility and affordability of screening programmes.

Editorial
Review Article

A comparison of ophthalmic education in China and America

:-
 

Abstract: Training qualified ophthalmic professional is crucial for any eye care system worldwide. Education of modern western Ophthalmology in China started late but develops rapidly. This review focused on ophthalmic education in China and US, describing details of the programs and analyzing the differences. This summary may provide useful information for practitioners of medical education from both countries and help improve the present training designs.

Original Article

Short-term observation of management of sclera patch grafts used in the scleral defects

:-
 

Background: To explore the safety and effectiveness of Sclera patch grafts in the management of scleral defects.

Methods: This is a retrospective uncontrolled study. Medical records were retrospectively reviewed for 8 eyes of 8 patients with sclera patch grafts. Two patients had necrotizing scleritis, 2 patients had scleral melting/perforation secondary to thermal burns, 4 patients had scleral staphyloma secondary to surgery. Sclera was reconstructed with allogenic sclera patch grafts, 6 in 8 patients combined autologous conjunctival pedicle flap, 1 patient combined partial medial rectus translocation, 1 patient combined autologous pedicle tenon graft, simultaneously. Treatment outcomes were evaluated using structural integrity, best corrected visual acuity (BCVA), scleritis remission, sclera rejection and melt, and ocular symptoms.

Results: Eight patients were reviewed. In all of these cases, satisfactory anatomic and functional outcomes were achieved. In the at least half a year follow-up, the BCVA of all the eight patients were no worse than that of preoperative. No eye pain, foreign body sensation and other discomforts showed in all the patients, except one woman, who showed sclera rejection and melt 1 month postoperative. In addition, one patient showed high intraocular pressure (28 mmHg), which can be controlled by a kind of medicine.

Conclusions: In this series, sclera patch grafts is an effective method for management scleral defects in the at least half a year following-up. Attention should be paid to the sclera patch rejection and melt post operatively.

其他期刊
  • 眼科学报

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
  • Eye Science

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
出版者信息