Cornea and Anterior segment

AB092. Database for the anatomopathological, functional and surgical characterization of the cornea

:-
 

Background: The purpose of this infrastructure is to provide to the Network researchers a database and diverse related tools for the anatomical and functional analysis of the normal, pathological and surgical cornea.

Methods: This database is composed of normal and pathological individuals, totaling more than 36,000 patients. It includes anatomical and functional imaging data, physiological optics data, psychometric and clinical data (medical history, surgical parameters, acuteness, etc.). Various corneal topography tools were added, giving the database a unique character: tools for analyzing individual maps, average map tools for the study and comparison of populations, 3D modeling and visualization tools, statistical tools, etc. There are also screening tools for detecting various corneal conditions (LASIK, PRK, RK, keratoconus) and for secure data exchange between colleagues.

Results: Several studies were made in recent years thanks to this common infrastructure. For example, this database has provided important information regarding the evolution of the 3D shape of the normal cornea with age and ametropia and has confirmed the mirror symmetry of corneas for the right and the left eyes (enantiomorphism). The different stages of Fuchs’ dystrophy were also characterized to provide essential knowledge for surgery of the posterior layer of the cornea. Our database also allowed studying the anatomy of the wounds and the shape of the cornea before and after a transfixing transplant or an endothelial transplant (DSAEK and DSEK). The data on the characterization of experimentally transplanted corneas with corneal equivalents generated by tissue engineering and the recent addition of clinical data on the replacement of a diseased cornea with a synthetic corneal equivalent (keratoprosthesis) also resulted in several publications. More recently, the database has allowed to develop innovative algorithms to determine the optimal shape of an implant according to the clinical parameters of the recipient. On the other hand, we also demonstrated that the 3D shape of the cornea can be used as a biometric characteristic (such as fingerprints) for identification of individuals for various applications ranging from forensics to secure border crossings. Consequently, a new multimodal database (cornea + iris + eventually retina) was created for the purpose of biometric identifications. This database provides a unique set of anatomical and functional tools for the analysis of the cornea. It is characterized by the scientific quality and large quantity of accumulated information on the cornea and the high-level tools to exploit its content.

Conclusions: The common infrastructure is easily accessible to all VHRN members on request. The database will also be accessible online in 2018 (see http://cvl.concordia.ca for more information).

Cornea and Anterior segment
Cornea and Anterior segment

AB083. Intraocular lens biocompatibility: a novel, objective approach

:-
 

Background: Understanding factors that contribute to posterior capsular opacification (PCO) development is a significant public concern as treatment can lead to complications. In order to prevent PCO, a better understanding of intraocular lens (IOL) characteristics, including design and material, and patient interaction is required. Herein, we performed a retrospective multivariable analysis to determine which factors (IOL and patient based) were least likely to result in PCO.

Methods: One hundred eighty post-mortem eyes with implanted IOLs were collected from the Minnesota Eye Bank, along with clinical history, including date of cataract surgery and IOL model number. The capsular bag (CB) with the IOL implant was removed from all eyes to obtain digital images. PCO outcome was quantified on CB images using an objective, automated custom image analyzer (Medical Parachute Automated Detector Opacification Software). The software measured intensity and area of the opacification within the IOL optic edge, intra-optic edge (IOE = intensity/area), and in Soemmering’s ring (SR = intensity/area). Epidemiologic analysis assessed which IOL characteristics and patient-related factors correlated with PCO. IOL factors included material, edge design, lens filter, company, IOL model, decentration and time from cataract surgery to death. Patient factors included sex, age and diabetes, among others.

Results: Multivariate analyses showed non-diabetic patients had less PCO (P=0.05). Individuals 50–80 years old compared to 80+ had lower SR PCO (P=0.04). Non-blue light filter IOLs had lower SR and IOE PCO compared to filter IOLs (P=0.03, 0.001). Square and frosted optic edge design had lower SR and IOE PCO rates compared to OptiEdge and round optic edge design (P=0.002, 0.02). The IOL model that had the least PCO was the ZA9003 model, but this was only significant for SR and not IOE PCO (P=0.04). Adjusting for patient-factors, IOL lens model was no longer a confounding factor for PCO. Patients with an IOL implanted for <7 years had lower SR PCO, whereas lower IOE PCO was only seen in implants <4 years old (P=0.0001, 0.04).

Conclusions: In order to generate a lens that does not develop PCO, it is critical to understand the IOL- and patient-related factors that lead to PCO development. Based on our data, the most susceptible patients are elderly and diabetic, and it may be preferable to implant a square and frosted edge lens without blue-light filtering in this cohort.

Review Article

The present and the prospect of bioengineering cornea

:-
 

Abstract: Corneal blindness represents one of the world’s three major causes of blindness, and the fundamental problem of corneal transplantation is a severe shortage of donor tissues worldwide, resulting in approximately 1.5 million new cases of blindness annually. To address the growing need for corneal transplants two main approaches are being pursued: allogenic and bioengineering cornea. Bioengineering corneas are constructed by naturally generating an extracellular matrix (ECM) component as the scaffold structure with or without corneal cells. It is well established that the scaffold structure directs the fate of cells, therefore, the fabrication of the correct scaffold structure components could produce an ideal corneal substitute, able to mimic the native corneal function. Another key factor in the construction of tissue engineering cornea is seed cells. However, unlike the epithelium and stroma cells, human cornea endothelium cells (HCECs) are notorious for having a limited proliferative capacity in vivo because of the mitotic block at the G1 phase of the cell cycle due to “contact-inhibition”. This review will focus on the main concepts of recent progress towards the scaffold and seed cells, especially endothelial cells for bioengineering cornea, along with future perspectives.

Review Article

The development of tissue engineering corneal scaffold: which one the history will choose?

:-
 

Abstract: Since the 21st century, the development of corneal tissue engineering technology has been developing rapidly. With the progress of biomaterials, cell culture and tissue engineering technology, tissue engineering cornea has gained great development in both basic scientific research and clinical application. In particular, tissue engineered corneal scaffolds are the core components of tissue engineered corneas. It is the focus of current research on tissue engineering cornea to search for scaffolds with good biocompatibility, high safety and good biomechanical properties. In this paper, the recent research progress of tissue engineering corneal materials is reviewed.

Review Article

Scleral remodelling in myopia and its manipulation: a review of recent advances in scleral strengthening and myopia control

:-
 

Abstract: The biological mechanisms of eye growth and refractive development are increasingly well characterised, a result of many careful studies that have been carried out over many years. As the outer coat of the eye, the sclera has the ultimate impact on the restraint or facilitation of eye growth, thus any changes in its biochemistry, ultrastructure, gross morphology and/or biomechanical properties are critical in refractive error development and, in particular, the development of myopia. The current review briefly revisits our basic understanding of the structure and biomechanics of the sclera and how these are regulated and modified during eye growth and myopia development. The review then applies this knowledge in considering recent advances in our understanding of how the mechanisms of scleral remodelling may be manipulated or controlled, in order to constrain eye growth and limit the development of myopia, in particular the higher degrees of myopia that lead to vision loss and blindness. In doing so, the review specifically considers recent approaches to the strengthening of the sclera, through collagen cross-linking, scleral transplantation, implantation or injection of biomaterials, or the direct therapeutic targeting and manipulation of the biochemical mechanisms known to be involved in myopia development. These latest approaches to the control of scleral changes in myopia are, where possible, placed in the context of our understanding of scleral biology, in order to bring a more complete understanding of current and future therapeutic interventions in myopia, and their consequences.

Review Article

Ophthalmic surgery teaching

:-
 

Abstract: The outcomes of modern ophthalmic surgery, especially cataract surgery, continue to improve and patients now realistically expect an excellent and speedy outcome with good vision and few complications. Social and regulatory demands for greater transparency and accountability in medicine have increased, highlighting a fundamental ethical tension in medical education—balancing the needs of trainees (who have not yet mastered the technique) to gain experience by performing surgery, with patient safety and the needs of the public to be protected from risk. Patient safety and well-being are the paramount considerations in any training program and must be the first consideration in program design. A variety of different educational strategies, each implemented with the aim of improving operative skills assessment and teaching, has recently been described in the literature. Effective use of these educational tools, combined with a structured approach to teaching and providing meaningful feedback, could improve outcomes, decrease complications and improve the quality and efficiency of surgical training in ophthalmology. Supervisors must assess their teaching style and communication, as being a good surgeon does not necessarily make a good trainer. Open disclosure must be given to patients about who will be performing the surgery, and communication during surgery between supervisors and trainees must be clear, respectful and appropriate.

Review Article
Review Article

Refractive surgical corrective options after cataract surgery

:-
 

Abstract: Cataract surgery is one of the most commonly performed surgeries among the elderly today. The volume of cataract surgeries has dramatically increased in the past few decades due to technological advancements leading to decreased morbidity, better overall outcomes, and increased expectation for correction of refractive error and spectacle independence after cataract surgery. The number of cataract surgeries is expected to continue to rise with the increase of the elderly population. Thus, accurate predictions of intraocular lens (IOL) power and the ability to correct for any postoperative refractive errors are critical. Despite the improved ability of cataract surgeons to accurately calculate IOL power, postoperative refractive errors still do occur due to various reasons such as imperfect preoperative measurements, toric-lens misalignment, and existing or surgically-induced astigmatism. The aim of this article is to review the various surgical options, including intraocular and corneal refractive surgical approaches, to correct post-operative refractive errors after cataract surgery.

Review Article

Multifocal and extended depth of focus intraocular lenses

:-
 

Abstract: Advances in intraocular lens (IOL) design have rendered cataract surgery a refractive procedure. Newer IOL types include bifocal, trifocal and extended depth of focus (EDOF) IOLs. Their basic difference nestles in the number of focal points that each lens provides, which in turn leads to different visual outcomes. Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs. In this review, we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance, intermediate and near vision, contrast sensitivity, and reading performance. Finally, we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL.

其他期刊
  • 眼科学报

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
  • Eye Science

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
出版者信息