2018年4月 第3卷 第4期

主管:中华人民共和国教育部
主办:中山大学
承办:中山大学中山眼科中心
主编:Ge Jian, Liu Yizhi
Review Article
Original Article

Objective electrophysiological contrast sensitivity with monofocal and multifocal intraocular lenses: a prospective clinical study

Objective electrophysiological contrast sensitivity with monofocal and multifocal intraocular lenses: a prospective clinical study

:-
 

Background: To compare objective electrophysiological contrast sensitivity function (CSF) in patients implanted with either multifocal intraocular lenses (MIOLs) or monofocal intraocular lenses (IOLs) by pattern reversal visual evoked potentials (prVEP) measurements.

Methods: Fourty-five cataract patients were randomly allocated to receive bilaterally: apodized diffractive-refractive Alcon Acrysof MIOL (A), full diffractive AMO Tecnis MIOL (B) or monofocal Alcon Acrysof IOL (C). Primary outcomes: 1-year differences in objective binocular CSF measured by prVEP with sinusoid grating stimuli of 6 decreasing contrast levels at 6 spatial frequencies. Secondary outcomes: psychophysical CSF measured with VCTS-6500, photopic uncorrected distance (UDVA), and mesopic and photopic uncorrected near and intermediate visual acuities (UNVA and UIVA respectively).

Results: Electrophysiological CSF curve had an inverted U-shaped morphology in all groups, with a biphasic pattern in Group B. Group A showed a lower CSF than group B at 4 and 8 cpd, and a lower value than group C at 8 cpd. Psychophysical CSF in group A exhibited a lower value at 12 cpd than group B. Mean photopic and mesopic UNVA and UIVA were worse in monofocal group compared to the multifocal groups. Mesopic UNVA and UIVA were better in group B.

Conclusions: Electrophysiological CSF behaves differently depending on the types of multifocal or monofocal IOLs. This may be related to the visual acuity under certain conditions or to IOL characteristics. This objective method might be a potential new tool to investigate on MIOL differences and on subjective device-related quality of vision.

Perspective

Degenerative myopia: mechanical theories revisited

Degenerative myopia: mechanical theories revisited

:-
 

Abstract: The article discusses the early abandonment of mechanical theories about eye enlargement in degenerative myopia at the turn of the 20th century. At that time, the number of theories about myopia grew unrestricted, but with scant support from the experimental field. The mechanical theories vanished as a new wave of metabolism-based theories appeared, propelled by the huge advances in molecular biology. Modern techniques allow reconsidering those theories and to put them to test with higher confidence.

其他期刊
  • 眼科学报

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
  • Eye Science

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
出版者信息