人工智能(artificial intelligence,AI)在白内障手术中的应用越来越广泛,二者结合对于白内障手术的术前诊断和分级管理、术中人工晶状体选择、位置预测及术后管理(视力预测、并发症预测及随访)、手术培训和教学方面均起到巨大的促进作用。诚然,AI在与白内障手术相关的管理、分析和研究中还面临着许多问题,但其广泛的应用前景不可忽视。现对AI在白内障手术治疗和教学中的应用做以总结,并对其未来的发展做出展望。
Artificial intelligence (AI) has been widely used in cataract surgery. The combination of the two can play a great role in improving preoperative diagnosis, grading management of cataract surgery, intraoperative intraocular lens selection and location prediction, postoperative management (vision prediction, complication prediction and follow-up), surgical training and teaching. It is true that AI still faces many problems in the management, analysis and research related to cataract surgery, but its broad application prospects cannot be ignored. This review summarizes the application of AI in cataract surgery and teaching, and the future prospects of AI.
传统的眼底手术要求眼科医生具备精细的操作技术,但即便拥有再精湛的操作技术,眼底手术还是存在很大的风险性。因此,为了减少手术风险,提高手术质量,对传统眼底手术进行改进是十分必要的。近年来,在我国对于人工智能产业的大力支持之下,应用于各类行业的机器人随之诞生。机器人辅助系统(robot auxiliary system,RAS)在医学领域,特别是眼科学中应用广泛。对近几年RAS应用于眼底手术的案例进行整理总结,并将RAS参与的眼底手术以及传统的眼底手术进行对比,可以发现RAS在眼底手术中的应用可以显著提高手术效率,并降低手术风险。未来RAS的发展趋势可能着重聚焦于与深度学习算法的紧密结合。通过算法对手术中的视野图像进行预测、优化,从而让高精度的眼底手术更加高效、安全。
Traditional fundus surgery requires ophthalmologists to be equipped with sophisticated operating techniques, but even with the most sophisticated operating techniques, fundus surgery still has great risks. Therefore, in order to reduce the risk of surgery and improve the quality of surgery, it is very necessary to improve the traditional fundus surgery. In recent years, with China’s strong support for the artificial intelligence industry, robots used in various industries have been born. Robot auxiliary system (RAS) is widely used in the medical field, especially in ophthalmology. By summarizing the cases of fundus surgery with RAS in recent years and comparing the fundus surgery involving RAS with traditional fundus surgery, it can be found that the application of RAS in fundus surgery can significantly improve the efficiency of surgery and reduce the risk of surgery. The future development trend of RAS may focus on the close integration with deep learning algorithms, which can predict and optimize the field of view images during surgery so that high-precision fundus surgery can be more efficient and safer.
目的:探讨青光眼日间手术患者的自我管理行为现状及影响因素分析。方法:采用便利抽样法选取2021年9月—2022年5月于广州市某三级甲等眼科专科医院就诊的223例青光眼日间手术患者。采用一般资料调查表、青光眼自我管理行为量表、慢性疾病自我效能量表和青光眼知识学习问卷进行问卷调查。结果:青光眼日间手术患者的自我管理行为得分为(54.03±6.95)分,其中生活调整维度得分最低。慢性病自我效能与自我管理行为呈正相关(r=0.368, P<0.001)。疾病知识与自我管理行为无显著相关性(r=0.077, P=0.252)。多因素线性回归分析结果显示,患者的文化程度(P<0.001)和自我效能(P=0.028)是自我管理行为的影响因素,可解释自我管理行为总变异的12.4%。结论:青光眼日间手术患者具有良好的自我管理行为,较低的自我效能和文化程度是自我管理行为的危险因素,因此应优先提高患者的自我效能,并提供个性化教育。
Objective: To determine self-management and its association with self-efficacy and knowledge among glaucoma patients undergoing day surgery. Methods: A total of 223 glaucoma patients were recruited from September 2021 to May 2022and they were investigated with the Glaucoma Self Management Questionnaire (GSMQ), The Self- Efficacy in Chronic Disease Scale (SECD-6), and the glaucoma knowledge questionnaire. Results: Of the 223 study participants, the study population had a total GSMQ score of 54.03±6.95 with the lowest score found in the life adjustment dimension. The total SECD-6 score was showing a significantly positive correlation with the total GSMQ score(r =0.368, P <0.001). The total score of disease knowledge was without significant correlation with the total GSMQ score (r =0.077, P =0.252). Multivariate linear regression analysis showed that self-efficacy (P <0.001) and education level was independently associated with self-management(P =0.028). Conclusions: Glaucoma patients undergoing daytime surgery demonstrated good overall self-management, yet further improvement was required in terms of life adjustment. Low self-efficacy and educational level were identified as risk factors for self-management. Therefore, self-management programs should prioritize enhancing patients' self-efficacy and delivering individualized education.
目的:分析角膜后前表面曲率半径比值(B/F比值)与年龄相关性白内障患者术后屈光误差的关系,探讨B/F比值对人工晶状体(intraocular lens,IOL)度数计算精确性的影响。方法:选取2019年3—11月在天津医科大学眼科医院白内障中心就诊,并拟行单眼白内障手术的年龄相关性白内障患者共197例(197眼),术前应用Pentacam眼前节分析仪测量患者眼前节生物参数,并以B/F比值下限25%、上限25%为界将患者分为下25%组、25%~75%组、上25%组。术后3个月应用全自动电脑验光仪评估患者术后屈光状态,并计算患者术后屈光误差(postoperative refractive error,PE),比较三组平均屈光误差(mean refractive error,ME)、平均绝对误差(mean absolute error,MAE)、中位数绝对误差(median absolute error,MedAE)以及屈光误差在±0.25、±0.50、±0.75、±1.00、>±1.00 D范围内百分比差异。结果:B/F比值与年龄相关性白内障患者术后屈光误差呈中度相关(r=?0.445, P<0.001)。随着B/F比值增大,患者术后屈光状态由远视向近视漂移,术后3个月MAE、MedAE分别为0.55 D、0.46 D。屈光误差在±0.25、±0.50、±0.75、±1.00、>±1.00 D范围的百分比分别为29.4%、52.8%、71.6%、87.6%、12.7%。根据正常年龄相关性白内障人群B/F比值优化得到的矫正角膜折射指数计算角膜曲率后,MAE、MedAE分别为0.51、0.43 D,均低于矫正前(P<0.05)。结论:B/F比值对年龄相关性白内障患者术后屈光状态有影响。随着B/F比值的增加,白内障患者术后屈光状态由远视逐渐向近视漂移,且B/F比值越偏离正常平均值,患者的屈光误差绝对值越大。
Objective: To analyze the relationship between corneal B/F ratio and postoperative refractive error in age-related cataract patients, and to explore the impact of B/F ratio on the accuracy of intraocular lens power calculation. Methods: A total of 197 age-related cataract patients (197 eyes) who were treated in the cataract center of our hospital from March 2019 to November 2019 and were going to undergo monocular cataract surgery were selected. The biological parameters of the anterior segment were measured by Pentacam anterior segment analyzer before surgery, and the patients were divided into three groups (25% below the B/F ratio, 25%~75%, and 25% below the B/F ratio) with the lower limit and the upper limit of 25%. Three months after surgery, the postoperative refractive state of patients was evaluated by automatic computerized refractometer, and the postoperative refractive error (PE) was calculated, and the percentage differences of mean refractive error (ME), mean absolute error (MAE), median absolute error (MedAE) and refractive error in the range of ±0.25, ±0.50, ±0.75, ±1.00 and < ±1.00D were evaluated. Results: The B/F ratio was moderately correlated with postoperative refractive error in age-related cataract patients (r= ?0.445, P < 0.001). With the increase of B/F ratio, the refractive state of patients shifted from hyperopia to myopia after surgery, and the MAE and MedAE were 0.55 D and 0.46 D respectively in 3 months after surgery. The percentages of refractive error in the range of ±0.25, ±0.50, ±0.75, ±1.00 and < ±1.00 D were 29.4%, 52.8%, 71.6%, 87.6% and 12.7%, respectively. After adjusting the corneal curvature according to the B/F ratio of the population based on our previous study, MAE and MedAE were 0.51 D and 0.43 D, respectively, which were lower than those before correction (P< 0.05). Conclusions: There is a correlation between B/F ratio and postoperative refractive error in age-related cataract patients. As the B/F ratio increased, the refractive state of the patient gradually drifted from farsightedness to myopia after cataract surgery, and the more the B/F ratio deviated from the normal average, the greater the absolute value of the patient's refractive error.
前段巨眼(anterior megalophthalmos, AM)是一种罕见的双侧非进展性先天性眼前段增大疾病,表现为大角膜(直径≥ 12.5 mm)、前房极深、角膜厚度正常或轻中度变薄和睫状环扩大等。并发性白内障以及晶状体脱位是导致AM视力下降的主要原因。然而,解剖结构的异常使AM白内障手术具有很大的挑战性。文章报道了一例AM合并白内障的48岁男性患者,成功为其行手法小切口白内障摘除联合人工晶状体(intraocular lens, IOL)一期植入术,患者术后视力恢复良好,IOL位置居中,未出现较大的屈光误差。对该典型AM病例的临床特点以及手术难点的回顾总结,有助于加深广大眼科临床工作者对该疾病的认识。
Anterior megalophthalmos is a rare congenital enlargement of the anterior segment, characterized by bilateral nonprogressive megalocornea (diameter ≥12.5 mm), extremely deep anterior chamber, normal or moderate thinning of the cornea, and elongation of the ciliary ring. Cataract and lens dislocation are the main causes of decreased vision in patients with AM. However, cataract surgery on patients with AM are challenging due to the anatomical abnormalities. This case reports a 48-year-old male patient diagnosed with AM and cataract, who successfully underwent a manual small incision cataract extraction combined with intraocular lens implantation. Finally, our patient showed a good visual outcome with a well centered IOL and without obvious refractive error. In this typical AM case, we reviewed and summarized the clinical characteristics and the challenges of surgical treatment so that other ophthalmologists can learn about this disease.
球形晶状体是一种罕见的先天性晶状体悬韧带疾病,表现为晶状体前后径增加,赤道半径减小,类似球形。临床特点包括浅前房、晶状体源性高度近视、晶状体脱位及继发青光眼等。治疗上早期可以通过验光配镜提高视力,当继发晶状体脱位及青光眼时需尽早进行手术治疗。本例报道一例72岁男性患者,因右眼视力下降2年入院。既往近视,近视逐渐加深,近2年患者双眼配镜-10D,视力无明显改善。就诊后考虑球形晶状体所致晶状体不全脱位合并白内障,入院后行囊袋拉钩固定下白内障超声乳化+人工晶状体悬吊+前段玻璃体切除术。患者术后1个月后复诊,发现黄斑水肿,予以复方平地木颗粒口服,溴芬酸钠滴眼液滴眼。2周后复诊视力及黄斑水肿明显好转。
Microspherophakia (MSP) is a rare congenital zonular dysplasia characterized by increased anteroposterior lens thickness and reduced equatorial diameter, resembling a spherical shape. The related ocular manifestations of MSP include shallow anterior chamber, lens derived high myopia, ectopia lentis and secondary glaucoma. In the early stage of MSP, vision acuity may be improved by glasses. Cataract surgery is necessary once secondary lens dislocation and glaucoma occur. A 72-year-old male hospitalized patient was reported who complained increased blurred vision of his right eye for 2 years. In the past 2 years, the power of his binocular glasses was increased to -10 diopters without significant improvement in visual acuity. Lens dislocation and phakic insufficiency caused by MSP was diagnosed after he attending clinics at the Eye and ENT Hospital of Fudan University, Shanghai, China. Phacoemulsification with scleral sutured intraocular lens (IOL) implantation surgery and anterior vitrectomy were performed. One month after operation, macular edema was found at first follow-up. Compound pingdingmu granule was taken orally and Bromfenac sodium eye drops were applied three times a day. Two weeks later, visual acuity of his right eye was improved significantly and macular edema was eliminated dramatically.
玻璃体视网膜疾病并发白内障患者行玻璃体切割术联合超声乳化白内障摘除术,即前后节联合手术,是高效的手术方式,而后囊膜破裂(posterior capsular rupture,PCR)是超声乳化白内障摘除术的术中并发症之一,能够及时、有效地处理PCR,稳定、安全地植入人工晶状体(intraocular lens,IOL),对于顺利完成后段手术,减少术后并发症十分重要。本文将对前后段联合手术中后囊膜破裂的术中处理、以及IOL光学部夹持固定法植入IOL的手术技术要点进行总结。
Combined surgery of pars plana vitrectomy (PPV) and phacoemulsification is an effective and safe way for management of retinal diseases complicated with cataract. Posterior capsular rupture (PCR) is one of the common intraoperative complications of phacoemulsification, and it is thus very important to deal with it promptly and efficiently, and ensure the subsequent procedures of intraocular lens (IOL) implantation as well as PPV. We will summarize the key points of the surgical technique for management of PCR and capture of IOL optic during combined surgery.
该文报道了一例40岁女性患者,因“双眼渐进性视物模糊3个月”就诊。患者既往于2005年因高度近视行双眼准分子激光原位角膜磨镶术 (LASIK)。最佳矫正视力OD:0.2 (–11.00 DS/ –1.25 DC×170 °),OS:0.7 (–4.00 DS/ –0.75 DC×25 °)。双眼角膜透明,前房中深,晶状体混浊,豹纹状眼底伴后巩膜葡萄肿。诊断为双眼并发性白内障,并行右眼白内障超声乳化联合人工晶状体 (IOL) 植入术,术中植入+14.0 D IOL一枚,目标屈光度为–0.5 D。术后1周裸眼视力0.3,验光结果示右眼屈光度+2.75 DS,最佳矫正视力0.7。术后2周行右眼IOL置换术,由+14.0 D置换为+17.0 D。右眼术后1周裸眼视力0.8,验光结果示右眼屈光度–0.75 DC×15 °。
It is reported in this article that a 40-year-old female patient presented with "progressive blurred vision of both eyes for 3 months". The patient underwent bilateral laser in situ keratomileusis (LASIK) because of high myopia in 2005. It was recorded that her best corrected visual acuity was 0.2 (–11.00 DS/ –1.25 DC×170 °) in the right eye and 0.7 (–4.00 DS/ –0.75 DC×25 °) in the left, and clear cornea, normal anterior chamber, cloudy lens, tessellated fundus with posterior staphyloma in both eyes. The patient was diagnosed with bilateral complicated cataract. Phacoemulsification combined with intraocular lens (IOL, +14.0 diopter (D)) implantation was performed on the right eye, with the target –0.5D refractive diopter . One week after surgery, it was recorded that the uncorrected visual acuity of the right eye was 0.3, and the best corrected visual acuity was 0.7 (+2.75 DS). IOL replacement of the right eye was performed two weeks after surgery, the +14.0 D IOL was replaced by +17.0 D IOL. One week after surgery, the uncorrected visual acuity of the right eye was 0.8 (–0.75 DC×15 °).
目的:通过对改良“Z”形无线结经巩膜缝线固定人工晶状体手术和传统有线结巩膜缝线固定人工晶状体手术治疗先天性晶状体脱位的比较来评价改良术式的临床疗效。方法:回顾性病例研究。纳入2018年1月—2021年3月期间于中山大学中山眼科中心行手术治疗的先天性晶状体脱位患者73例73眼,按手术方式不同将患者分为无线结组36例36眼和有线结组37例37眼。比较两组患者术前和术后1年的球镜度(DS)、柱镜度(DC)、等效球镜(SE)、最佳矫正视力(BCVA)、眼压(IOP)、眼轴长度(AL)、角膜内皮细胞计数和术后并发症的发生率。结果:两组患者术前各项观察指标组间比较差异无统计学意义(均P>0.05)。两组患者术后1年 BCVA 均较术前提高(均P<0.05),SE均较术前降低(均P<0.05)。两组患者术后1年 BCVA 、DS、DC、SE、IOP、AL、角膜内皮细胞丢失率组间比较差异均无统计学意义(均P>0.05)。术后1年,有线结组有5例(13.5%)出现缝线暴露,无线结组未出现缝线暴露,组间比较差异有统计学意义(P<0.05)。结论:改良无线结 IOL 巩膜缝线固定手术可改善CEL患者的最佳矫正视力和屈光不正,有效减少缝线暴露及相关并发症。
Objective: To evaluate the clinical efficacy of modified “Z”-shaped knotless transscleral suture fixation intraocular lens (IOL) and traditional knotted transscleral suture fixation IOL in congenital ectopia lentis. Methods: A retrospective case study. A total of 73 eyes of 73 patients with congenital ectopia lentis who underwent surgical treatment in our hospital from January 2018 to March 2021 were included. According to different surgical methods, the patients were divided into the knotless group (36 eyes) and knotted group (37 eyes). Preoperative and postoperative of 1-year diopter sphere (DS), diopter cylinder (DC), spherical equivalent (SE), best corrected visual acuity (BCVA), intraocular pressure (IOP), and axial length (AL), corneal endothelial cell counts and the occurrence of postoperative complications rate were analyzed among two groups. Results: There was no significant difference in preoperative outcome measures between the two groups (P>0.05). BCVA at 1-year postoperative was significantly better (P<0.05), and SE at 1-year postoperative was significantly lower (P<0.05). There was no significant difference in BCVA, DS, DC, SE, IOP, AL, and corneal endothelial cell loss rate between the two groups at 1-year after operation (P>0.05). One year after the operation, there were 5 cases of suture exposure (13.5%) in the knotted group and no suture exposure in the knotless group, and the difference was statistically significant (P<0.05). Conclusions: The modified knotless IOL transscleral suture fixation can improve the best corrected visual acuity and alleviate ametropia of CEL patients, and reduce suture exposure and related complications effectively.
目的:在硅油取出联合白内障手术患者中,使用扫频源光学相干断层扫描生物测量仪OA-2000进行生物测量,比较10种人工晶状体(IOL)屈光力计算公式的准确性。方法:回顾性分析2021年3月—7月于中山大学中山眼科中心接受硅油取出联合白内障手术的患者共62例(62眼),所有患者均使用扫频源光学相干断层扫描生物测量仪OA-2000进行生物学参数测量。计算并比较新公式[Barrett Universal II (BUII)、Emmetropia Verifying Optical(EVO) 2.0、Hill-Radial Basis Function (Hill-RBF) 3.0、Hoffer QST、Kane、Pearl-DGS]及传统公式(Haigis、Hoffer Q、Holladay 1、SRK/T)的预测准确性,主要评价指标为绝对预测误差中位数(MedAE)及平均绝对预测误差(MAE)。按眼轴长度≤23 mm(组1),>23 mm且≤26 mm(组2)与>26 mm(组3)进行亚组分析。结果:6个新公式、Haigis、SRK/T公式均出现近视漂移(-0.47 ~-0.27 D,P<0.05),而HofferQ及Holladay 1公式无系统误差(P>0.05)。Kane公式的MedAE(0.55 D)及MAE(0.81 D)最小,但公式间比较差异无统计学意义(P>0.05)。组1中所有公式均出现近视漂移(-1.46~ -1.25 D,P<0.05),而其他亚组比较差异无统计学意义(-0.32 ~ 0.41 D,P>0.05)。在组1中,Pearl-DGS公式的MedAE(0.97 D)及MAE(1.26 D)最小,且优于Hill-RBF 3.0(P=0.01)及SRK/T公式(P=0.02);组2中,Kane公式具有最小的MedAE(0.44 D)及MAE(0.66 D);组3各个公式屈光预测准确性比较差异无统计学意义(P>0.05)。结论:在使用OA-2000进行术前生物测量时,Kane公式在接受硅油取出联合白内障手术患者中的预测准确性较高;而眼轴长度≤23 mm时,Pearl-DGS公式可能更为准确。
Objective: To compare the accuracy of 10 intraocular lens (IOL) power calculation formulas in patients undergoing combined silicone oil removal and cataract surgery, biometry is performed using the swept-source optical coherence tomography biometer OA-2000. Methods: A retrospective analysis. A total of 62 patients (62 eyes) who underwent combined silicone oil removal and cataract surgery in Zhongshan Ophthalmic Center, Sun Yat-sen University from March to July in 2021 were enrolled. Preoperative biometry was performed by OA-2000 in all patients. New-generation formulas (Barrett Universal II [BUII], Emmetropia Verifying Optical [EVO] 2.0, Hill-Radial Basis Function [Hill-RBF] 3.0, Hoffer QST, Kane and Pearl-DGS) and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T) were evaluated. The median absolute prediction error (MedAE) and mean absolute prediction error (MAE) were the main parameters used to assess accuracy. Subgroup analyses were performed based on the axial length of 23 mm and 26 mm. Results: Six new-generation formulas, Haigis, and SRK/T showed myopic shift (-0.47 ~ -0.27 D, P<0.05), while no systematic bias was found in Hoffer Q and Holladay 1 displayed (P>0.05). The smallest MedAE (0.55 D) and MAE (0.81 D) were found in Kane formula, but there was no statistically significant difference compared with other formulas (P>0.05). The myopic shift (-1.46 ~ -1.25 D, P<0.05) in eyes shorter than 23 mm were found in all formulas, while there was no significant systematic bias (-0.32 ~ 0.41 D, P>0.05) in other subgroups. In axial length shorter than 23 mm, the Pearl-DGS formula stated the smallest MedAE (0.97 D) and MAE (1.26 D), and was significantly more accurate than Hill-RBF 3.0 (P=0.01) and SRK/T (P=0.02). In eyes with an axial length between 23 mm and 26 mm, the Kane formula had the lowest MedAE (0.44 D) and MAE (0.66 D). No significant difference was found in eyes longer than 26 mm. Conclusion: The Kane formula showed the highest accuracy in patients undergoing combined silicone oil removal and cataract surgery measured by OA-2000, whereas the Pearl-DGS formula could be more accurate in eyes with an axial length shorter than 23 mm.