Original Article

A virtual model of the retina based on histological data as a tool for evaluation of the visual fields

A virtual model of the retina based on histological data as a tool for evaluation of the visual fields

:-
 

Background: To settle the fundamentals of a numerical procedure that relates retinal ganglion-cell density and threshold sensitivity in the visual field. The sensitivity of a generated retina and visual pathways to virtual stimuli are simulated, and the conditions required to reproduce glaucoma-type defects both in the optic-nerve head (ONH) and visual fields are explored.

Methods: A definition of selected structural elements of the optic pathways is a requisite to a translation of clinical knowledge to computer programs for visual field exploration. The program is able to generate a database of normalized visual fields. The relationship between the number of extant receptive fields and threshold sensitivity is plotted for background sensitivity and corresponding automated perimetry. A solution in two planes to the 3D distribution of axons in the ONH is proposed. Visual fields with induced damage in the optic disc are comparable in pattern and quantity to glaucomatous records.

Results: The two-level simulation of the ONH facilitates the analysis of optic-cup/retinal defects. We can generate the virtual optic pathways tailored to the age and morphology of the patient’s eye, and it is possible to reproduce glaucomatous damage by “reverse engineering” engineering. The virtual cortical model renders a quantitative relationship between visual defect and neural damage.

Conclusions: A two-level computing of the retina/optic nerve facilitates the analysis of neuroretinal defects and can be incorporated to automatic perimeters to facilitate visual field analysis.

Background: To settle the fundamentals of a numerical procedure that relates retinal ganglion-cell density and threshold sensitivity in the visual field. The sensitivity of a generated retina and visual pathways to virtual stimuli are simulated, and the conditions required to reproduce glaucoma-type defects both in the optic-nerve head (ONH) and visual fields are explored.

Methods: A definition of selected structural elements of the optic pathways is a requisite to a translation of clinical knowledge to computer programs for visual field exploration. The program is able to generate a database of normalized visual fields. The relationship between the number of extant receptive fields and threshold sensitivity is plotted for background sensitivity and corresponding automated perimetry. A solution in two planes to the 3D distribution of axons in the ONH is proposed. Visual fields with induced damage in the optic disc are comparable in pattern and quantity to glaucomatous records.

Results: The two-level simulation of the ONH facilitates the analysis of optic-cup/retinal defects. We can generate the virtual optic pathways tailored to the age and morphology of the patient’s eye, and it is possible to reproduce glaucomatous damage by “reverse engineering” engineering. The virtual cortical model renders a quantitative relationship between visual defect and neural damage.

Conclusions: A two-level computing of the retina/optic nerve facilitates the analysis of neuroretinal defects and can be incorporated to automatic perimeters to facilitate visual field analysis.

Perspective
Editorial
Review Article

Femtosecond laser-assisted cataract surgery (FLACS) in resident training

Femtosecond laser-assisted cataract surgery (FLACS) in resident training

:-
 

Abstract: This article reviews the history of the femtosecond laser in ophthalmology and its subsequent introduction into the field of cataract surgery. It discusses the innovations that this technology has brought to the field. The article also describes the current system of teaching cataract surgery to ophthalmology residents in the United States and then examines how femtosecond laser-assisted cataract surgery (FLACS) can be a beneficial part of residency education.

Abstract: This article reviews the history of the femtosecond laser in ophthalmology and its subsequent introduction into the field of cataract surgery. It discusses the innovations that this technology has brought to the field. The article also describes the current system of teaching cataract surgery to ophthalmology residents in the United States and then examines how femtosecond laser-assisted cataract surgery (FLACS) can be a beneficial part of residency education.

Editorial
Original Article

Objective electrophysiological contrast sensitivity with monofocal and multifocal intraocular lenses: a prospective clinical study

Objective electrophysiological contrast sensitivity with monofocal and multifocal intraocular lenses: a prospective clinical study

:-
 

Background: To compare objective electrophysiological contrast sensitivity function (CSF) in patients implanted with either multifocal intraocular lenses (MIOLs) or monofocal intraocular lenses (IOLs) by pattern reversal visual evoked potentials (prVEP) measurements.

Methods: Fourty-five cataract patients were randomly allocated to receive bilaterally: apodized diffractive-refractive Alcon Acrysof MIOL (A), full diffractive AMO Tecnis MIOL (B) or monofocal Alcon Acrysof IOL (C). Primary outcomes: 1-year differences in objective binocular CSF measured by prVEP with sinusoid grating stimuli of 6 decreasing contrast levels at 6 spatial frequencies. Secondary outcomes: psychophysical CSF measured with VCTS-6500, photopic uncorrected distance (UDVA), and mesopic and photopic uncorrected near and intermediate visual acuities (UNVA and UIVA respectively).

Results: Electrophysiological CSF curve had an inverted U-shaped morphology in all groups, with a biphasic pattern in Group B. Group A showed a lower CSF than group B at 4 and 8 cpd, and a lower value than group C at 8 cpd. Psychophysical CSF in group A exhibited a lower value at 12 cpd than group B. Mean photopic and mesopic UNVA and UIVA were worse in monofocal group compared to the multifocal groups. Mesopic UNVA and UIVA were better in group B.

Conclusions: Electrophysiological CSF behaves differently depending on the types of multifocal or monofocal IOLs. This may be related to the visual acuity under certain conditions or to IOL characteristics. This objective method might be a potential new tool to investigate on MIOL differences and on subjective device-related quality of vision.

Background: To compare objective electrophysiological contrast sensitivity function (CSF) in patients implanted with either multifocal intraocular lenses (MIOLs) or monofocal intraocular lenses (IOLs) by pattern reversal visual evoked potentials (prVEP) measurements.

Methods: Fourty-five cataract patients were randomly allocated to receive bilaterally: apodized diffractive-refractive Alcon Acrysof MIOL (A), full diffractive AMO Tecnis MIOL (B) or monofocal Alcon Acrysof IOL (C). Primary outcomes: 1-year differences in objective binocular CSF measured by prVEP with sinusoid grating stimuli of 6 decreasing contrast levels at 6 spatial frequencies. Secondary outcomes: psychophysical CSF measured with VCTS-6500, photopic uncorrected distance (UDVA), and mesopic and photopic uncorrected near and intermediate visual acuities (UNVA and UIVA respectively).

Results: Electrophysiological CSF curve had an inverted U-shaped morphology in all groups, with a biphasic pattern in Group B. Group A showed a lower CSF than group B at 4 and 8 cpd, and a lower value than group C at 8 cpd. Psychophysical CSF in group A exhibited a lower value at 12 cpd than group B. Mean photopic and mesopic UNVA and UIVA were worse in monofocal group compared to the multifocal groups. Mesopic UNVA and UIVA were better in group B.

Conclusions: Electrophysiological CSF behaves differently depending on the types of multifocal or monofocal IOLs. This may be related to the visual acuity under certain conditions or to IOL characteristics. This objective method might be a potential new tool to investigate on MIOL differences and on subjective device-related quality of vision.

Cornea and Anterior segment
Cornea and Anterior segment
Brain and Perception

AB073. Correlations between control of saccadic eye movements and performance in other cognitive tasks in younger adults, older adults and patients with Parkinson’s disease

AB073. Correlations between control of saccadic eye movements and performance in other cognitive tasks in younger adults, older adults and patients with Parkinson’s disease

:-
 

Background: Cognitive control is defined as the ability to act flexibly in the environment by either behaving automatically or inhibiting said automatic behaviour and it can be measured using an interleaved pro/anti-saccade task. Decline in cognitive control has been attributed to normal aging and neurological illnesses such as Parkinson’s disease (PD) as well as decline in other cognitive abilities. This parallel might highlight the role played by cognitive control in information processing and working memory. However, little is known about the relationship between cognitive control and other cognitive processes such as visual memory, decision making, and visual search. We thus propose to correlate the incidence of impaired cognitive control with deficits in visual memory, decision making and visual search in three groups: younger adults, older adults and patients with idiopathic PD.

Methods: Seventy-one participants, namely 34 adults (M =22.75, SD =3.8), 22 older adults (M =67.4, SD =8.3), and 20 PD patients (M =65.59, SD =8.2) performed four tasks: interleaved pro/anti-saccade, visual memory, decision making, and serial and pop-out visual search.

Results: Results show that within each group, anti-saccade error rate (ER) were significantly and negatively correlated with visual memory ER (ryounger =?0.378, P=0.036; rolder =?0.440, Polder =0.046; rPD =?0.609, P=0.016). On the other hand, correct decision-making reaction times (RT) were significantly correlated with anti-saccade ER, and RTs only in older adults (rER =0.529, P=0.014; rRT =0.512, P=0.018) and PD patients (rER =0.727, P=0.012; rRT =0.769, P=0.001). For visual search, PD patients showed a significant relationship between RTs for correct pro-saccades and pop-out (r=0.665, P=0.007), and serial (r=0.641, P=0.010) search RTs. Furthermore, there was a significant correlation between MoCA scores and anti-saccade RTs (r=?0.559, P=0.030) and ER (r=?0.562, P=0.029) in PD patients. Taken together, these results support the hypothesis of PD patients’ reliance on bottom-up processes as top-down processes decline. For younger adults, there was a significant correlation between serial search performance and both anti-saccade ER (r=0.488, P=0.005), and correct pro-saccade ER (r=0.413, P=0.021). In older adults, this relationship was absent, but anti-saccade ER significantly correlated with pop-out search times (r=0.473, P=0.030).

Conclusions: We found significant relationships between cognitive tasks and cognitive control as measured through the interleaved pro/anti-saccade task across and within participant groups, providing evidence of the appropriateness of the use of the interleaved pro/anti-saccade task as a measure of overall cognitive control.

Background: Cognitive control is defined as the ability to act flexibly in the environment by either behaving automatically or inhibiting said automatic behaviour and it can be measured using an interleaved pro/anti-saccade task. Decline in cognitive control has been attributed to normal aging and neurological illnesses such as Parkinson’s disease (PD) as well as decline in other cognitive abilities. This parallel might highlight the role played by cognitive control in information processing and working memory. However, little is known about the relationship between cognitive control and other cognitive processes such as visual memory, decision making, and visual search. We thus propose to correlate the incidence of impaired cognitive control with deficits in visual memory, decision making and visual search in three groups: younger adults, older adults and patients with idiopathic PD.

Methods: Seventy-one participants, namely 34 adults (M =22.75, SD =3.8), 22 older adults (M =67.4, SD =8.3), and 20 PD patients (M =65.59, SD =8.2) performed four tasks: interleaved pro/anti-saccade, visual memory, decision making, and serial and pop-out visual search.

Results: Results show that within each group, anti-saccade error rate (ER) were significantly and negatively correlated with visual memory ER (ryounger =?0.378, P=0.036; rolder =?0.440, Polder =0.046; rPD =?0.609, P=0.016). On the other hand, correct decision-making reaction times (RT) were significantly correlated with anti-saccade ER, and RTs only in older adults (rER =0.529, P=0.014; rRT =0.512, P=0.018) and PD patients (rER =0.727, P=0.012; rRT =0.769, P=0.001). For visual search, PD patients showed a significant relationship between RTs for correct pro-saccades and pop-out (r=0.665, P=0.007), and serial (r=0.641, P=0.010) search RTs. Furthermore, there was a significant correlation between MoCA scores and anti-saccade RTs (r=?0.559, P=0.030) and ER (r=?0.562, P=0.029) in PD patients. Taken together, these results support the hypothesis of PD patients’ reliance on bottom-up processes as top-down processes decline. For younger adults, there was a significant correlation between serial search performance and both anti-saccade ER (r=0.488, P=0.005), and correct pro-saccade ER (r=0.413, P=0.021). In older adults, this relationship was absent, but anti-saccade ER significantly correlated with pop-out search times (r=0.473, P=0.030).

Conclusions: We found significant relationships between cognitive tasks and cognitive control as measured through the interleaved pro/anti-saccade task across and within participant groups, providing evidence of the appropriateness of the use of the interleaved pro/anti-saccade task as a measure of overall cognitive control.

Brain and Perception