Original Article

Day surgery in strabismus operation under general anesthesia

:-
 

Background: The purpose of this study is to summarize the application of day surgery combined with fast track program in strabismus operation under general anesthesia.

Methods: The clinical data of 2,000 cases of strabismus patients who had underwent surgery in day surgery or traditional hospitalization in the duration from 2015 to 2016 was retrospectively analyzed. The safety and efficacy were assessed by comparing the average length of stay in hospitals, anesthesia recovery time, patient satisfaction and number of adverse events.

Results: Compared with the traditional group, the average length of stay in hospital and recovery time in day surgery group were significantly lower (P<0.001) and the satisfaction of patient was improved (P<0.05), which were statistically significant difference. Moreover, no adverse events occurred among these patients.

Conclusions: The application of day surgery in strabismus operation under general anesthesia is feasible, which can reduce the recovery time and shorten the hospital stay of patients safely and effectively, and their satisfaction was improved at the same time.

Review Article

Update on indications for diabetic vitrectomy and management of complications

:-
 

Abstract: Despite appropriate management of the systemic disease, patients with diabetes may develop severe forms of diabetic retinopathy that require surgery. Non-clearing vitreous haemorrhage (VH), traction retinal detachment involving the macula, combined traction and rhegmatogenous retinal detachment, progressive fibrovascular proliferation (PFP) and rubeosis with acute VH represent the main indications for surgery. Vitrectomy techniques and surgical tools have developed dramatically in the last decade in order to help the surgeon succeed in these challenging cases.

Review Article

Progress and challenges in genome-wide studies to understand the genetics of diabetic retinopathy

:-
 

Abstract: There are many advantages to understanding the genetics of human disease. Genetic markers can be used to calculate the risk of developing a disease, and elucidation of genetic risk factors can pinpoint the molecular aetiology of disease, which can facilitate the development of targeted therapies. Diabetic retinopathy (DR) is a common complication of diabetes that has a significant impact on quality of life. It has a clear genetic component, but determination of the genetic risk factors has proven difficult. To date, genome-wide studies for DR have been conducted on relatively small patient cohorts compared to other complex eye diseases and replication of genetic findings has been limited. The disease is highly heterogeneous, confounding attempts to classify patients into appropriate groups for genetic analysis and making direct comparisons between studies challenging. Future studies to determine the genetic causes of DR will need to focus on larger sample sizes, detailed phenotyping and appropriate classification of patients. Global co-operation and meta-analyses combining data from multiple studies will be critical to the discovery of genetic risk loci for DR.

Review Article

New findings and challenges in OCT angiography for diabetic retinopathy

:-
 

Abstract: Diabetic retinopathy (DR) is a leading cause of visual loss worldwide. Disease severity is graded from mild non-proliferative DR to proliferative DR. Optical coherence tomography angiography (OCTA) has become widely accepted as a useful noninvasive technique that provides detailed imaging of the ocular vessels. It is also becoming an increasingly essential tool for both qualitative and quantitative assessment of DR, especially with the advent of wider imaging capabilities. Various angiographic features of DR, such as microaneurysms, intraretinal microvascular abnormalities, neovascularization, and nonperfusion have been comprehensively studied and described using OCTA. Different quantitative OCTA metrics have been introduced, such as vessel density, foveal avascular zone (FAZ) area, and area of nonperfusion. Current research has been focusing on the application of quantitative OCTA for the diagnosis of DR and treatment monitoring. The primary purpose of this article is to review the use of OCTA, including its challenges, in the diagnosis and management of DR.

Original Article
Review Article

Ischemic optic neuropathies—update

:-
 

Abstract: This submission will briefly review the anatomy and physiology of the optic nerve, and highlight various ischemic optic neuropathies including anterior ischemic optic neuropathies (non-arteritis and arteritic), diabetic papillopathy, posterior ischemic optic neuropathies, and ischemic optic neuropathies in the setting of hemodynamic compromise.

Review Article

The role of optical coherence tomography in neuro-ophthalmology

:-
 

Abstract: Optical coherence tomography (OCT) is an ocular imaging technique that can complement the neuro-ophthalmic assessment, and inform our understanding regarding functional consequences of neuroaxonal injury in the afferent visual pathway. Indeed, OCT has emerged as a surrogate end-point in the diagnosis and follow up of several demyelinating syndromes of the central nervous system (CNS), including optic neuritis (ON) associated with: multiple sclerosis (MS), neuromyelitis optica spectrum disorder (NMOSD), and anti-myelin oligodendrocyte glycoprotein (MOG) antibodies. Recent advancements in enhanced depth imaging (EDI) OCT have distinguished this technique as a new gold standard in the diagnosis of optic disc drusen (ODD). Moreover, OCT may enhance our ability to distinguish cases of papilledema from pseudopapilledema caused by ODD. In the setting of idiopathic intracranial hypertension (IIH), OCT has shown benefit in tracking responses to treatment, with respect to reduced retinal nerve fiber layer (RNFL) measures and morphological changes in the angling of Bruch’s membrane. Longitudinal follow up of OCT measured ganglion cell-inner plexiform layer thickness may be of particular value in managing IIH patients who have secondary optic atrophy. Causes of compressive optic neuropathies may be readily diagnosed with OCT, even in the absence of overt visual field defects. Furthermore, OCT values may offer some prognostic value in predicting post-operative outcomes in these patients. Finally, OCT can be indispensable in differentiating optic neuropathies from retinal diseases in patients presenting with vision loss, and an unrevealing fundus examination. In this review, our over-arching goal is to highlight the potential role of OCT, as an ancillary investigation, in the diagnosis and management of various optic nerve disorders.

Review Article

Design and recent results of large-scale cohort epidemiology studies on refractive error in children in Shanghai

:-
 

Abstract: Between 2011 and 2013, two large-scale cohort epidemiology studies were launched in Shanghai: the SCALE study, which aimed to provide ocular public health services to cover the entire youth population in Shanghai, and the SCES, which was based on sample surveys and aimed to provide information on the prevalence and incidence of visual impairment and different types of refractive errors. A total of 910,245 children and adolescents were finally enrolled in the SCALE study; three possible methods for monitoring refractive error without mydriasis were tested, and the agreement between the refractive outcomes of three commonly used autorefractors were examined to ensure the accuracy of the results of the SCALE study. A total of 8,627 children were enrolled in the SCES, and the baseline prevalence of different refractive errors, different behaviors associated with 1 year myopic shifts, and the different patterns of 2-year myopia progression between internal migrant and local resident school children have been analyzed. In some subset samples of the SCALE study and the SCES, several refraction components such as choroidal thickness (ChT) and crystalline lens power were also measured, to further elucidate the relationships between the refraction components and myopia as well as the mechanism of myopia incidence and development. The three methods used in Shanghai to prevent and intervene with childhood myopia: increasing outdoor time, low concentration atropine, and use of orthokeratology lens are also addressed in this review.

Original Article
Original Article

Objective electrophysiological contrast sensitivity with monofocal and multifocal intraocular lenses: a prospective clinical study

:-
 

Background: To compare objective electrophysiological contrast sensitivity function (CSF) in patients implanted with either multifocal intraocular lenses (MIOLs) or monofocal intraocular lenses (IOLs) by pattern reversal visual evoked potentials (prVEP) measurements.

Methods: Fourty-five cataract patients were randomly allocated to receive bilaterally: apodized diffractive-refractive Alcon Acrysof MIOL (A), full diffractive AMO Tecnis MIOL (B) or monofocal Alcon Acrysof IOL (C). Primary outcomes: 1-year differences in objective binocular CSF measured by prVEP with sinusoid grating stimuli of 6 decreasing contrast levels at 6 spatial frequencies. Secondary outcomes: psychophysical CSF measured with VCTS-6500, photopic uncorrected distance (UDVA), and mesopic and photopic uncorrected near and intermediate visual acuities (UNVA and UIVA respectively).

Results: Electrophysiological CSF curve had an inverted U-shaped morphology in all groups, with a biphasic pattern in Group B. Group A showed a lower CSF than group B at 4 and 8 cpd, and a lower value than group C at 8 cpd. Psychophysical CSF in group A exhibited a lower value at 12 cpd than group B. Mean photopic and mesopic UNVA and UIVA were worse in monofocal group compared to the multifocal groups. Mesopic UNVA and UIVA were better in group B.

Conclusions: Electrophysiological CSF behaves differently depending on the types of multifocal or monofocal IOLs. This may be related to the visual acuity under certain conditions or to IOL characteristics. This objective method might be a potential new tool to investigate on MIOL differences and on subjective device-related quality of vision.