Original Article

Comparison of ocular biometry in Chinese patients using two swept-source optical coherence tomography devices

:22-77
 
Background: To compare two swept-source optical coherence tomography (SS-OCT) biometers,IOLMaster 700 and ANTERION.
Methods: This is a retrospective study. Biometric measurements of cataract patients performed between March and July 2021 in the Department of Ophthalmology, United Christian Hospital, Hong Kong, were reviewed. Patients scheduled for cataract surgery were measured with both SS-OCT devices on the same day.The following biometry parameters were compared: keratometry (K), total keratometry (TK), axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), white-to-white (WTW) and the predicted intraocular lens (IOL) power to achieve emmetropia. To assess the agreement between the devices, Bland-Altman analysis with 95% limits of agreement (LoA) were used.
Results: In total, 92 eyes of 47 subjects were measured with both devices. There were statistically significant differences between the two biometers for most measurements (P<0.05) except for flat K, AL and IOL power when using the right eyes for analysis. For the left eyes, there were statistically significant differences in the measurements from the two biometers in all parameters except for flat and steep K. The ANTERION did not obtain ACD, AL and LT in 2 (2.17%), 1 (1.09%) and 5 cases (5.43%) respectively.
Conclusions: The two biometers showed a clinically acceptable agreement in most parameters. Comparisons showed significant differences in most parameters but not clinically relevant except for the TK and WTW, and these two parameters should not be used interchangeably between the devices.
Case report

Case report: simultaneous femtosecond laser astigmatic keratotomy and toric intraocular lens implantation in femtosecond laser-assisted cataract surgery in a patient with surgically induced high corneal astigmatism

:-
 

Background: Femtosecond laser astigmatic keratotomy (FSAK) and toric intraocular lens (IOL) implantation have been studied individually for comparison to treat astigmatism at cataract surgery. We report a case of surgically induced high corneal astigmatism by laser thermal keratoplasty (LTK) in a patient with cataract who was successfully treated with simultaneous combination of FSAK and toric IOL implantation with femtosecond laser-assisted cataract surgery (FLACS). This is the first report of both procedures combined simultaneously, with or without history of LTK.

Case Description: A 68-year-old male presented with a history of LTK with two enhancements each eye in 2004, with subsequent surgically induced high corneal astigmatism, and with age-related nuclear cataract of both eyes. IOL master demonstrated +7.71 diopters of astigmatism at 163 degree right eye and +3.29 diopters of astigmatism at 4 degree left eye. After extensive discussion of the risks and benefits, the patient agreed to undergo FLACS with FSAK with two 61 degrees of relaxation incisions (RIs) and toric IOL (Alcon SN6AT9) right eye; FLACS with toric IOL (Alcon SN6AT7) alone left eye. At 2-year follow-up, uncorrected visual acuity was 20/30 right eye, 20/25 left eye. His best corrected visual acuity was 20/25 (+0.25 +1.00 axis 21) right eye and 20/20 (plano +0.25 axis 90) left eye; his best corrected near visual acuity was J1+ with add +2.50 diopters right eye and left eye.

Conclusions: Patients with age-related cataract and LTK induced high corneal astigmatism can hardly be sufficiently treated with FSAK or toric IOL alone at the time of cataract surgery. An effective way is to combine large FSAK and toric IOL of the highest cylindrical power of T9, in our case, simultaneously, which can achieve an excellent long term visual outcome.

Original Article

Supracapsular implantation with optic capture of posterior chamber intraocular lens in Chinese children with aphakic after traumatic cataract

:-
 

Background: To assess the safety and efficacy of supracapsular implantation with optic capture of the posterior chamber intraocular lens in Chinese children with aphakic after traumatic cataract.

Methods: It was a retrospective case series study. Fifteen cases (15 eyes) Chinese children received supracapsular implantation with optic capture of the posterior chamber intraocular lens. Pre- and post-operative visual acuities were recorded. Intra- and post-operative complications were observed. The follow-up period ranged from 7 to 43 (28.7±7.2) months.

Results: Implantation of optic capture of the posterior chamber intraocular lens was successfully performed in 15 eyes. The best corrected visual acuity (BCVA) ranged from 0.3 to 1.0 (0.61±0.19). No optic axis opaque was found in 15 eyes with optic capture. The major complications of optic capture were iris posterior synechia and intraocular lens (IOL) precipitates. Intraocular dislocation was found in one case three weeks after the operation.

Conclusions: Supracapsular implantation with optic capture of the posterior chamber intraocular lens is safe and effective for the treatment of traumatic cataract in Chinese children.

Review Article

Workplace-based assessments

:-
 

Abstract: The goal of ophthalmology residency training is to produce competent ophthalmologists. Appropriate assessments must be employed to ensure this goal is met. Valid and reliable workplace-based assessments are designed to assess competence in the many domains required of a good ophthalmologist. These assessments increase standardization and objectivity as compared to simple observational feedback. When used appropriately, workplace based assessments not only provide measures of competence but also facilitate effective formative feedback and enhance learning.

Original Article

Simplified pupilloplasty technique through a corneal paracentesis to manage small iris coloboma or traumatic iris defect

:-
 

Background: To report a new simplified surgical technique to manage small iris coloboma or traumatic iris defect.

Methods: A new surgical technique in which simplified pupilloplasty technique through only a clear corneal paracentesis to manage the iris coloboma or traumatic iris defect within the 120° range was designed. A retrospective revision of the medical records of patients treated with this technique between the years 2013 and 2016 was made. Six eyes of six patients with iris coloboma or traumatic iris defect treated with this new technique were included.

Results: All the operated eyes quickly recovered with central round pupil, negligible complications, inessential symptoms of photophobia and glare, and mild inflammation after a median follow-up time of 22 months (range: 6–34 months).

Conclusions: The simplified pupilloplasty technique presented here could be a good alternative for the management of small iris coloboma or traumatic iris defect.

Original Article

Combined pars plana vitrectomy and suture less scleral fixation of foldable intraocular lens: single surgery visual rehabilitation of dislocated lens/intraocular lens

:-
 

Background: To evaluate efficacy and safety of combined pars plana vitrectomy (PPV) and scleral fixated intraocular lens (SFIOL) surgery as a single procedure.

Methods: Retrospective interventional case series done at a tertiary eye care center in Northern India. Eleven patients who underwent combined PPV and SFIOL surgery were included and analyzed retrospectively.

Results: Mean age of the patients was 43.36±15.12 years (range, 22–64 years). Eight were male. Mean baseline best corrected visual acuity (BCVA) was 0.78±0.63 logMAR units while the mean post-operative BCVA at 6 months follow-up was 0.37±0.29 logMAR units, the visual gain being statistically significant (P=0.021). None of the patients had a drop in BCVA with nine patients having final BCVA better than 0.48 logMAR units. Choroidal detachment (CD) was the only notable complication, seen in three patients. Other complications included two cases of intraoperative retinal breaks, a case each of reversible corneal edema, ocular hypertension and cystoid macular edema.

Conclusions: Combined PPV and SFIOL is an efficacious procedure for managing IOL/lens dislocation and aphakia in a single surgery. There may be short-term reversible complications with no impact on final visual gain.

Editorial
Review Article

Femtosecond laser-assisted cataract surgery (FLACS) in resident training

:-
 

Abstract: This article reviews the history of the femtosecond laser in ophthalmology and its subsequent introduction into the field of cataract surgery. It discusses the innovations that this technology has brought to the field. The article also describes the current system of teaching cataract surgery to ophthalmology residents in the United States and then examines how femtosecond laser-assisted cataract surgery (FLACS) can be a beneficial part of residency education.

Cornea and Anterior segment

AB083. Intraocular lens biocompatibility: a novel, objective approach

:-
 

Background: Understanding factors that contribute to posterior capsular opacification (PCO) development is a significant public concern as treatment can lead to complications. In order to prevent PCO, a better understanding of intraocular lens (IOL) characteristics, including design and material, and patient interaction is required. Herein, we performed a retrospective multivariable analysis to determine which factors (IOL and patient based) were least likely to result in PCO.

Methods: One hundred eighty post-mortem eyes with implanted IOLs were collected from the Minnesota Eye Bank, along with clinical history, including date of cataract surgery and IOL model number. The capsular bag (CB) with the IOL implant was removed from all eyes to obtain digital images. PCO outcome was quantified on CB images using an objective, automated custom image analyzer (Medical Parachute Automated Detector Opacification Software). The software measured intensity and area of the opacification within the IOL optic edge, intra-optic edge (IOE = intensity/area), and in Soemmering’s ring (SR = intensity/area). Epidemiologic analysis assessed which IOL characteristics and patient-related factors correlated with PCO. IOL factors included material, edge design, lens filter, company, IOL model, decentration and time from cataract surgery to death. Patient factors included sex, age and diabetes, among others.

Results: Multivariate analyses showed non-diabetic patients had less PCO (P=0.05). Individuals 50–80 years old compared to 80+ had lower SR PCO (P=0.04). Non-blue light filter IOLs had lower SR and IOE PCO compared to filter IOLs (P=0.03, 0.001). Square and frosted optic edge design had lower SR and IOE PCO rates compared to OptiEdge and round optic edge design (P=0.002, 0.02). The IOL model that had the least PCO was the ZA9003 model, but this was only significant for SR and not IOE PCO (P=0.04). Adjusting for patient-factors, IOL lens model was no longer a confounding factor for PCO. Patients with an IOL implanted for <7 years had lower SR PCO, whereas lower IOE PCO was only seen in implants <4 years old (P=0.0001, 0.04).

Conclusions: In order to generate a lens that does not develop PCO, it is critical to understand the IOL- and patient-related factors that lead to PCO development. Based on our data, the most susceptible patients are elderly and diabetic, and it may be preferable to implant a square and frosted edge lens without blue-light filtering in this cohort.

Review Article
其他期刊
  • 眼科学报

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
  • Eye Science

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
出版者信息