剥脱性青光眼是剥脱综合征继发的一类青光眼,临床上少见。本文报告2例患者,患眼瞳孔缘可见灰白色碎屑样物质沉积,散大瞳孔后可见晶状体前囊周边部混浊带,房角镜下可见Sampaolesi线。认识其临床特征,将有助于提高其诊治率。
Exfoliation glaucoma is a category of glaucoma secondary to exfoliation syndrome, which is rarely encountered in clinical practice. We reported 2 cases with deposits of white material on the pupillary border of the iris. Opacity band could be observed surrounding the anterior lens capsule after pupil dilation, and the Sampaolesi line was seen under gonioscope. Understanding the clinical characteristics contribute to improving the diagnosis and treatment of exfoliation glaucoma.
息肉状脉络膜血管病变(polypoidal choroidal vasculopathy,PCV)是亚洲人中常见的眼底致盲性疾病,当PCV合并视网膜下出血或玻璃体积血(vitreous hemorrhage,VH)时,患者视力骤然下降,视力预后差异大。但目前聚焦于PCV合并VH的相关文献较少,因此研究和阐明PCV继发VH的治疗方法及预后具有重要的临床意义。目前临床上常选择手术干预,玻璃体切除术(pars plana vitrectomy,PPV)是临床上最常选择的一种术式。其他治疗方式包括玻璃体内注射抗血管内皮生长因子(vascular endothelial growth factor,VEGF)、眼内气体或硅油填充、眼内注射组织纤溶酶原激活剂(tissue plasminogen activator,tPA)和光动力疗法(photodynamic therapy,PDT)。PCV合并VH患者的视力预后决定因素是黄斑视功能的保留程度,也与年龄、术前视力、PCV病变部位、视网膜下出血量、视网膜脱离范围、基线黄斑中心厚度(central macular thickness,CMT)、是否出现术后并发症以及是否形成视网膜瘢痕等因素相关,目前也有研究发现视力预后与单核苷酸多态性(single nucleotide polymorphisms,SNP)相关。本文就PCV继发VH的临床特点、治疗及预后进行综述。
Polypoid choroidal vasculopathy (PCV) is a common fundus blinding disease in Asians. When PCV is associated with subretinal hemorrhage or vitreous hemorrhage (VH), patient's visual acuity decreases suddenly and the visual prognosis varies greatly. There are few relevant literatures focusing on VH secondary to PCV, so it is of great clinical significance to study and clarify the treatment methods and prognosis of VH secondary to PCV. At present, surgical intervention is often selected in clinical practice. Vitrectomy is the most commonly selected surgical procedure in clinical practice. The other treatment modalities include intravitreal injection of antivascular endothelial growth factor (VEGF), intraocular gas or silicone oil filling, intraocular injection of tissue plasminogen activator (tPA) and photodynamic therapy. The prognostic determinant of visual acuity in PCVpatients with VH is the degree of preservation of macular visual function. The prognostic is also related to age, preoperative visual acuity, PCV lesion location, amount of subretinal hemorrhage, extent of retinal detachment, baseline central macular thickness (CMT), postoperative complications and retinal scars. Recent studies also find that the prognosis of visual acuity is related to single nucleotide polymorphisms. This article reviews the clinical characteristics, treatment and visual prognosis of PCV associated with VH.
目的:分析医学人工智能通识课程“眼科人工智能的研发与应用”的开展效果,为相关医学人工智能通识课程的开展提供参考和借鉴。方法:纵向观察性研究。观察分析2020年秋季学期眼科人工智能的研发与应用通识课程学生人群,课程考核结果以及学生对课程的整体评价。结果:共有118名本科生同学参与了课程学习。其中大部分为低年级临床医学专业本科生。期中考核得分为77.21±10.07,有56位同学(47.46%)达到80分以上。期末考核得分为82.24±6.77,有91位同学(77.12%)达到80分以上。同学对课程的评分为98.76±3.55,超过90%的同学表示课程备课认真、授课条理清晰、表达准确。结论:本课程的顺利进展证明医学人工智能联合教学模式的可行性,理论和实践穿插的教学设置帮助同学们更好地掌握知识技术,完成教学目标。
Objective: To analyze the effectiveness of medical education curriculum named “Development and Application of Ophthalmic Artificial Intelligence”, and provide reference for the development of other related curriculums. Methods: Longitudinal observational study method was adopted. During the fall semester of 2020, we conducted an education curriculum named “Development and Application of Ophthalmic Artificial Intelligence” and analyzed the results of mid-term and final examinations, and curriculum evaluation of students. Results: There were 118 undergraduate students taking the course and most of them were junior students majoring in clinical medicine. The score of the mid-term examination was in the range of 77.2±10.07, and 56 students (47.46%) got more than 80 points. The score of the final examination was in the range of 82.24±6.77, and 91 students (77.12%) got more than 80 points. The score of course evaluation of students was in the range of 98.76±3.55, and more than 90% of the students thought that teachers have made full preparations before class, together with clear teaching logic and accurate expressions in class. Conclusion: The smooth progress of our course proved the feasibility of medical artificial intelligence teaching. The teaching setting interspersed with theory and practice could help students to master knowledge and technology better, so as to achieve the teaching objectives.
目的:探讨连续锁边缝合联合角膜绷带镜在翼状胬肉手术中应用的效果。方法:采用前瞻性随机对照临床研究。选取2018年1月到2021年6月期间在我院行翼状胬肉切除联合自体角膜缘结膜瓣移植术的患者132例180眼,按结膜瓣固定方式随机分为A、B两组,其中A组患者(64例90眼)行间断缝合固定法,B组患者(68例90眼)行连续锁边缝合法,术毕两组患者均给与配戴角膜绷带镜。比较两组患者的术后眼部疼痛程度评分、术后效果及并发症。结果:术后1、3 d,B组疼痛评分明显低于A组,差异有统计学意义(P<0.01);术后1、3、7 d两组间角膜染色评分差异无统计学意义(P>0.05);术前、术后3个月两组间泪膜破裂时间(breakup time of tear film,BUT)差异无统计学意义(P>0.05),但术后3个月组内的BUT较手术前有明显改善(P<0.05)。术前、术后2周两组间视力差异均无统计学意义(P>0.05),术后2周两组组内视力较手术前均有明显改善(P<0.05)。随访3个月,两组患者主要术后并发症包括胬肉撕除后浅层基质损伤延迟愈合、线结处结膜增生、结膜植片松脱等,并发症发生率两组相当。结论:采用连续锁边缝合联合配戴角膜绷带镜治疗翼状胬肉可以促进角膜创面的修复,减轻患者的术后刺激症状,提高患者术后舒适度;连续锁边缝合时需要适当增加缝线跨度,可减少术后结膜植片的松脱。
Objective: To investigate the effect of continuous locking suture combined with corneal bandage lens in the operation of pterygium. Methods: A prospective randomized controlled clinical trial was conducted. From January 2018 to June 2021, 132 patients (180 eyes) who underwent pterygium excision combined with autologous limbal conjunctival flap transplantation were randomly divided into group A and group B according to the fixation of conjunctival fla. The patients in group A (64 cases, 90 eyes) were treated with intermittent suture and fixation, and the patients in group B (68 cases, 90 eyes) were treated with continuous locking suture. Both groups were given corneal bandage lenses at the end of the operation. The postoperative ocular pain score, postoperative effect and complications were compared between the two groups. Results: The pain score in group B was significantly lower than that in group A at 1 and 3 d after operation (P<0.01), and there was no significant difference in corneal staining score between the two groups at 1, 3 and 7 d after operation (P>0.05). There was no significant difference in breakup time of tear film (BUT) between the two groups before and 3 months after operation (P>0.05), but the BUT at 3 months after operation in the group was significantly better than that before operation (P<0.05). There was no significant difference in visual acuity between the two groups before and 2 weeks after operation (P>0.05). The visual acuity of the two groups was significantly improved 2 weeks after operation (P<0.05). During the follow-up of 3 months, the main postoperative complications of the two groups included delayed healing of superficial matrix injury after pterygium avulsion, conjunctival hyperplasia, conjunctival graft loosening and so on. Conclusion: Continuous locking suture combined with corneal bandage lens in the treatment of pterygium can promote the repair of corneal wound, reduce the postoperative irritation symptoms and improve the postoperative comfort of patients. It is necessary to increase the suture span during continuous locking suture, which can reduce the loosening of conjunctival graft after operation.
目的:探讨光学相干断层扫描血管成像技术(optical coherence tomography angiography,OCTA)在斜视性弱视伴偏中心注视患者中应用的价值。方法:收集2018年1月到2020年5月斜视性弱视伴偏中心注视的患者17人为研究组,采用OCTA系统软件工具,以μm为单位测量视网膜固视点和黄斑中心凹之间的距离,同时收集非斜视、弱视且中心注视健康者17人为对照组,并分析受试者的浅层视网膜血管丛的黄斑中心凹血流长度密度(vessel length density,VLD)、灌注密度(perfusion density,PD)、黄斑中心凹无血流信号区(foveal avascular zone,FAZ)、面积、FAZ周长及FAZ圆形度。结果:斜视组弱视眼偏心距离为(632.18±310.62) μm,黄斑中心凹浅层血管丛VLD为(5.31±3.44) mm?1,PD为0.16±0.08,黄斑中心凹无血流信号区FAZ面积(0.28±0.17) mm2,FAZ周长(2.05±0.56) mm、FAZ圆形度0.67±0.06;与研究组対侧眼和对照组相比,VLD差异有统计学意义(P<0.05),PD、FAZ面积等差异无统计学意义(P>0.05)。斜视组弱视眼偏心度与偏中心距离显著相关(r=0.834,P<0.001)。结论:OCTA可以量化偏中心距离,斜视性弱视伴偏中心注视眼的黄斑中心凹血流长度密度较対侧眼及健康眼低。
Objective: To explore the application value of optical coherence tomography angiography (OCTA) in patients with strabismic amblyopia accompanied by eccentric fixation. Methods: Seventeen strabismus amblyopia patients with eccentric fixation admitted to our hospital from January 2018 to May 2020 were enrolled as the study group. OCTA software was used to measure the distance between fixation point and macular fovea in micron units. Seventeen non-strabismus and non-amblyopia patients with centric fixation were enrolled as the control group. Vessel length density (VLD), perfusion density (PD), and foveal avascular zone (FOZ) were measured for the superficial retinal vascular cluster. Perimeter of FAZ and circularity of FAZ were analyzed. Results: The eccentric fixation distance was (632.18 ±310.6) μm, the macular fovea retinal thickness was (207.82±17.79) μm, the VLD of the superficial retinal vascular plexus was (5.31±3.44) mm?1, the PD was 0.16±0.08, the FAZ area was 0.28±0.17 mm2, the FAZ perimeter was 2.05±0.56 mm, and the FAZ circularity was 0.67±0.06. These results showed statistically significant differences in the VLD compared with the fellow eyes (P=0.043) and the control group (P=0.049), but there were no statistically significant differences in the PD, or FAZ area. In the strabismus group, the eccentricity of amblyopia was significantly correlated with the eccentric distance (r=0.834, P<0.001). Conclusion: OCTA can quantify the eccentric distance. The blood flow length density of macular fovea in strabismic amblyopia with eccentric fixation is lower than that in contralateral and healthy eyes.
目的:评价StarEyes 900(万灵帮桥,中国)与IOLMaster 500(蔡司,德国)2种眼科光学生物测量仪测量健康受试者眼部参数的差异性、相关性及一致性。方法:前瞻性观察2021年6月至7月于中山大学中山眼科中心进行眼部检查的62例健康受试者共124只眼,分别通过StarEyes 900与IOLMaster 500完成眼轴长度(axial length,AL)、最小角膜屈光力径线上角膜曲率(keratometry for the flattest meridian,Kf)、最大角膜屈光力径线上角膜曲率(keratometry for the steepest meridian,Ks)、平均角膜曲率(mean keratometry,Km)、角膜白到白直径(white-to-white corneal diameter,WTW)等参数的测量,采用配对t检验、Pearson相关分析和Bland-Altman法对其测量结果的差异进行评价。结果:StarEyes 900与IOLMaster 500测量的AL分别为(24.18±1.08) mm和(24.16±1.08) mm;Kf分别为(42.84±1.65) D和(43.04±1.57) D;Ks分别为(44.34±1.90) D和(44.17±1.80) D;Km分别为(43.59±1.73) D和(43.61±1.64) D;WTW分别为(11.64±0.29) mm和(11.64±0.30) mm。StarEyes 900与IOLMaster 500在测量Km、WTW时,其差异无统计学意义(P>0.05),而在AL、Kf、Ks的测量上差异有统计学意义(P<0.01)。其中StarEyes 900所测的AL和Ks值大于IOLMaster 500,而Kf、Km和WTW值则小于IOLMaster 500。经Pearson相关分析,2种仪器的测量结果均表现出较高的相关性;经Bland-Altman法评价,2种仪器的测量结果均表现出较高的一致性。结论:StarEyes 900与IOLMaster 500测量的Km、WTW均表现出较高的一致性,2种方法可互为参考;测量的AL、Kf、Ks存在的差异具有统计学意义;各项参数的测量均具有较好的相关性和一致性。
Objective: To evaluate the difference, correlation and agreement of eye parameters measured by StarEyes 900 visual function analyzer (Wan Ling Bang Qiao, China) and IOLMaster 500 (Carl Zeiss, Germany) swept-source optical coherence tomography biometer. Methods: A prospective study was designed involving 62 healthy subjects (124 eyes) undergoing ophthalmic examinations in Zhongshan Ophthalmic Center from June 2021 to July 2021. Data from their both eyes were selected for analysis in all patients. Axial length (AL), keratometry for the steepest meridian (Ks), keratometry for the flattest meridian (Kf), mean keratometry (Km) and corneal diameter (WTW) were measured by the StarEyes 900 visual function analyzer and IOLMaster 500 swept-source optical coherence tomography biometer. A paired t-test was used to analyze the differences in measurement results. The Pearson correlation coefficient was used to analyze the correlation. Bland-Airman method was used to assess the agreement of the instruments. Results: The AL, Kf, Ks, Km and WTW obtained by StarEyes 900 and IOLMaster 500 were (24.18±1.08) mm and (24.16±1.08) mm, (42.84±1.65) D and (43.04±1.57) D, (44.34±1.90) D and (44.17±1.80) D, (43.59±1.73) D and (43.61±1.64) D, and (11.64±0.29) mm and (11.64±0.30) mm, respectively. The Km and WTW of the two devices showed no significant difference (P>0.05), while the AL, Ks and Kf showed significant differences (all P<0.01). The AL and Ks obtained by StarEyes 900 were higher than by IOLMaster 500, while the Kf, Km and WTW were lower. The measurements of five aforementioned biometric parameters by both devices showed good correlation by Pearson correlation coefficient and good agreement by Bland-Airman. Conclusion: The Km and WTW measured by the two devices showed no significant difference, and provided references to one another. The difference in AL, Kf and Ks between the two devices showed significant differences. All of the measurements showed good correlation by Pearson correlation coefficient and good agreement by Bland-Airman.
目的:比较角膜生物力学分析仪(Corvis ST)、A型超声测厚仪(A超)、Lenstar LS 900(Lenstar)在测量近视眼角膜厚度的差异,为屈光术前筛查提供参考。方法:纳入2020年3至12月佛山市第二人民医院收治的屈光术前近视患者244例(244只右眼),并按中央角膜厚度(central corneal thickness,CCT)将患者分为3组:薄角膜组(CCT≤520 μm)、正常角膜组(520 μm570 μm),分别采用Corvis ST、A超、Lenstar三种仪器测量3组患者的中央角膜厚度,并纳入对比指标。结果:Corvis ST与A超、Lenstar在薄角膜组、正常角膜组、厚角膜组的测量值对比差异均有统计学意义(均P<0.05);在相关性方面,Corvis ST与A超、Lenstar在薄角膜组、正常角膜组、厚角膜组呈正相关(r=0.841,P<0.001 vs r=0.832,P<0.001;r=0.866,P<0.001 vs r=0.918,P<0.001;r=0.497,P<0.001 vs r=0.801,P<0.001);在一致性方面,Corvis ST与A超、Lenstar在薄角膜组、正常角膜组、厚角膜组上一致性系数ICC及95%置信区间分别为0.602(0.091,0.857),0.758(0.221,0.901)、0.741(0.207,0.890),0.845(0.396,0.938)、0.417(0.005,0.679),0.667(0.172,0.851),95%一致性区间范围分别是(-2.2~24.2 μm,-6.7~19.5 μm;-8.4~24.6 μm,-6.8~19.4 μm;-8.7~23.8 μm,-7.0~18.3 μm)。结论:通过对3组数据统计分析得出,Corvis ST与A超、Lenstar的测量值相比,差异均有统计学意义,且Corvis ST的测量值均高于后两种仪器;Corvis ST与后两者均有着较高的相关性,且在正常角膜厚度测量上相关性最高;在一致性方面,从ICC点估计及95%置信区间数值分析,一致性较差;从Bland-Altman角度分析,Corvis ST与后两者的绝对值最大差值超过10 μm,一致性较差,但在与Lenstar的绝对值最大差值均在20 μm内。因此,在测量精度要求较高的屈光手术筛查方面,Corvis ST与A超、Lenstar之间不能相互替代,而对于大规模临床筛查,其角膜厚度测量值对眼压的影响有一定的临床参考意义。
Objective: To compare the differences of corneal thickness measured by corneal biomechanical analyzer (Corvis ST), A-mode ultrasonic thickness meter (A-ultrasound) and Lenstar LS 900 (Lenstar) in myopia, so as to provide reference for preoperative screening of refractive surgery. Methods: A total of 244 patients (244 right eyes) with myopia before refractive surgery in Foshan Second People’s Hospital from March to December 2020 were included in the study, and the patients were divided into three groups according to the central corneal thickness (CCT): the thin cornea group (CCT≤520 μm), the normal cornea group (520 μm570 μm). The central corneal thickness (CCT) of the three groups was measured by Corvis ST, A-type ultrasonic thickness gauge and Lenstar LS 900, respectively, and included in the comparison index. Results: The measured values of Corvis ST, A-ultrasound and Lenstar in the thin cornea group, the normal cornea group and the thick cornea group were statistically significant (all P<0.05). Corvis ST was positively correlated with A-ultrasound and Lenstar in the thin cornea group, the normal cornea group and the thick cornea group (r=0.841, P<0.001 vs r=0.832, P<0.001; r=0.866, P<0.001 vs r=0.918, P<0.001; r=0.497, P<0.001 vs r=0.801, P<0.001). In terms of consistency, the consistency coefficients ICC of Corvis ST, A-ultrasound and Lenstar in the thin cornea group, the normal cornea group and the thick cornea group were 0.602 (0.091, 0.857), 0.758 (0.221, 0.901); 0.741 (0.207, 0.890), 0.845 (0.396, 0.938); 0.417 (0.005, 0.679), 0.667 (0.172, 0.851), and the range of 95% consistency interval were -2.2–24.2 μm, -6.7–19.5 μm; -8.4–24.6 μm, -6.8–19.4 μm; -8.7–23.8 μm, -7.0–18.3 μm. Conclusion: Through the statistical analysis of the data from the three groups, it is concluded that the measured values of Corvis ST are statistically significant compared with those of A-ultrasound and Lenstar, and the measured values of Corvis ST are higher than those of the latter two instruments. Corvis ST has a high correlation with the latter two, and the correlation is the highest in the measurement of normal corneal thickness. In terms of consistency, from the ICC point estimation and 95% confidence interval numerical analysis, the consistency was poor. From the perspective of Bland Altman, the maximum absolute value difference between Corvis ST and Lenstar was more than 10 μm, indicating poor consistency, but the maximum absolute value difference between Corvis ST and Lenstar was within 20 μm. Therefore, in refractive surgery screening with high measurement accuracy, Corvis ST, A-ultrasound and Lenstar cannot replace each other. However, in large-scale clinical screening, the measured value of corneal thickness has a certain clinical reference significance on the impact of intraocular pressure.