Review Article
Review Article

Choriocapillaris in non-neovascular age-related macular degeneration as evaluated by optical coherence tomography angiography

:-
 

Abstract: Dramatic advances in retinal imaging technology over the last two decades have significantly improved our understanding of the natural history and pathophysiology of non-neovascular age-related macular degeneration (AMD). Currently, aside from micronutrient supplements, there are no proven treatments for non-neovascular or dry AMD. Recently, a number of pharmacological agents have been evaluated or are under evaluation for treatment of patients with end-stage dry AMD manifesting as geographic atrophy (GA). It may preferable, however, to intervene earlier in the disease before the development of irreversible loss of visual function. Earlier intervention would require a more precise understanding of biomarkers which may increase the risk of progression from early and intermediate stages to the late stage of the disease. The development of optical coherence tomography angiography (OCTA) has allowed the layers of the retinal microcirculation and choriocapillaris (CC) to be visualized and quantified. Flow deficits in the CC have been observed to increase with age, particularly centrally, and these flow deficits appear to worsen with development and progression of AMD. As such, OCTA-based CC assessment appears to be a valuable new biomarker in our assessment and risk-stratification of AMD. Alterations in the CC may also provide new insights into the pathophysiology of the disease. Enhancement of choriocapillaris function may also prove to be a target of future therapeutic strategies or as a biomarker to monitor the effectiveness of therapy. As such, CC imaging may be anticipated to be an integral tool in the management of dry AMD.

Review Article

Rapid retinal functional testing

:-
 

Abstract: The most prominent causes of loss of vision in individuals over 50 years include age-related macular degeneration (AMD), glaucoma, and diabetic retinopathy (DR). While it is important to screen for these diseases effectively, current eye care is not properly doing so for much of the population, resulting in unfortunate visual disability and high costs for patients. Innovative functional testing can be unified with other screening methods for a more robust and safer screening and prediction of disease. The goal in the creation of functional testing modalities is to develop highly sensitive screening tests that are easy to use, accessible to all users, and inexpensive. The tests herein are deployed on an iPad with easily understood and intuitive instructions for rapid, streamlined, and automatic administration. These testing modalities could become highly sensitive screenings for early detection of potentially blinding diseases. The applications from our collaborators at AMA Optics include a cone photostress recovery test for detection of AMD and diabetic macular edema (DME), brightness balance perception for optic nerve dysfunction and especially glaucoma, color vision testing which is a broad screening tool, and visual acuity test. Machine learning with the combined structural and functional data will optimize identification of disease and prediction of outcomes. Here, we review and assess various tests of visual function that are easily administered on a tablet for screening in primary care. These user-friendly and simple screening tests allow patients to be identified in the early stages of disease for referral to specialists, proper assessment and treatment.

Review Article

Update on biologic therapies for juvenile idiopathic arthritis-associated uveitis

:-
 

Abstract: Juvenile idiopathic arthritis (JIA) is the most common rheumatic disease of childhood, and juvenile idiopathic associated uveitis (JIA-U) is the most frequently noted extra-articular manifestation. JIA-U can present asymptomatically and lead to ocular complications, so regular screening and monitoring are needed to prevent potentially sight-threatening sequelae. Topical glucocorticoids such as prednisolone acetate are usually the first line of treatment for anterior uveitis associated with JIA-U, but long-term use may be associated with cataract, ocular hypertension and glaucoma. Disease modifying anti-rheumatic drugs (DMARDs) such as methotrexate allow tapering of the corticosteroids to prevent long-term complications. Biologic therapies have been increasingly used as targeted therapies for JIA-U, particularly monoclonal antibodies targeting the proinflammatory cytokine TNF-α such as adalimumab and infliximab. One recent, multicenter, prospective, randomized clinical trial provided evidence of the efficacy of adalimumab with methotrexate for JIA-U compared to methotrexate alone. Another clinical trial studying the interleukin-6 inhibitor tocilizumab for JIA-U showed promise in tapering topical corticosteroids. Additionally, JAK inhibitors are emerging biologic therapies for JIA-U in patients refractory to TNF-α inhibitors, with a clinical trial assessing the efficacy of baricitinib for JIA-U underway. While clinical trials on these novel biologics are limited, further investigation of these agents may provide additional therapeutic options for JIA-U.

Review Article
Original Article

Folded technique of self-adherent wrap improves clinical outcomes for wounds after orbital tumour extirpation: a single-center, prospective randomized controlled trial

:-
 

Background: Using a randomized controlled trial (RCT), to assess the efficacy of the folded technique of self-adherent wrap to eyes after orbital tumour extirpation and compare it with the classic technique.

Methods: A single-centre, prospective, randomized, controlled study was conducted among 128 patients who underwent orbital tumour extirpation in this study. The folded and classic techniques of applying self-adherent wraps were randomly allocated to patients (1:1). The primary endpoint was the interface pressure on the affected eye. Secondary efficacy endpoints were the interface pressure above and below the ear of the affected side, above the ear of the non-affected side, and discomfort scores. Postoperative complications were observed for 24 hours.

Results: The interface pressure with the folded technique on the affected eye was neither inferior nor superior to the classic technique (1.33±0.07 vs. 1.41±0.09 mmHg, P=0.480). Most importantly, the pressure at three other points outside of the affected eye, including above and below the ear of the affected side, and above the ear of the non-affected side, were significantly higher when using the classic technique than when using the folded technique (P=0.041, 0.019, and 0.047, respectively). Discomfort scores were higher in the classic technique group than in the folded technique group (2.93±0.30 vs.1.52±0.19, P≤0.001).

Conclusions: Findings demonstrated the advantages of using folded technique to apply self-adherent wrap for wounds after orbital tumour extirpation with lower interface pressure outside of the affected eye and patient discomfort scores, without influencing pressure on the affected eye comparing with the classic technique.

Review Article

Three-dimensional anthropometry in periorbital region

:-
 

Abstract: Anthropometry can analyze the size, weight, and proportion of the human body objectively and quantitatively to supplement the visual assessment. Various non-invasive three-dimensional (3D) anthropometric techniques have been applied to assess soft tissues’ 3D morphology in the clinical practice. Among them, non-invasive stereophotogrammetry and laser scanning techniques are becoming increasingly popular in craniofacial surgery and plastic surgery. They have been applied for craniofacial growth estimation and morphometric investigation, genetic and acquired malformation diagnosis, as well as orthodontic or surgical treatment arrangement and outcome evaluation. However, few studies have been published for assessing the 3D morphology of soft tissues in the periorbital region. This paper reviews the studies involving the application and evaluation of the increasingly popular 3D photogrammetry in the periorbital region. These studies proposed detailed and standardized protocols for three-dimensionally assessing linear, curvilinear, angular, as well as volumetric measurements, and verified its high reliability in the periorbital region (even higher than caliper-derived direct measurements). In the future, reliable and accurate 3D imaging techniques, as well as standardized analyzing protocols, may find applications in following up morphological growth, preoperatively diagnosing and assessing patient periorbital conditions, planning surgical procedures, postoperatively evaluating treatment outcomes of a specific procedure, and comparing the differences in surgical results between various procedures, studies, as well as populations.

Review Article

Narrative review of goniotomy with the Kahook Dual Blade for the treatment of glaucoma

:-
 

Abstract: Glaucoma is a group of eye diseases that seriously threaten human visual health. Increased intraocular pressure is the main clinical manifestation and diagnostic basis of glaucoma and is directly related to increased resistance to aqueous circulation channels. The trabecular meshwork (TM) is a multi-layer spongy tissue that filters aqueous humor. Its structure changes and the filtering capacity decreases, leading to an increase in intraocular pressure. Surgical methods for TM are constantly updated. Compared with traditional glaucoma surgical techniques, such as external trabeculectomy, the development of a new surgical technique—minimally invasive glaucoma surgery (MIGS)—enables the operation to reduce intraocular pressure efficiently while further reducing damage to the eye. MIGS achieves the purpose of surgery mainly by optimizing the TM outflow pathway, uveoscleral outflow pathway, and subconjunctival outflow pathway. A new surgical instrument, the Kahook Dual Blade, appears to optimize the TM outflow pathway in the surgical technique. The Kahook Dual Blade is a new type of angle incision instrument. Because of its unique double-edged design, in the process of goniotomy, it can effectively reduce the damage to the anterior chamber angle structure and accurately remove the appropriate amount of TM so that the aqueous humor can flow out smoothly. Kahook Dual Blade goniotomy has the advantages of avoiding complications and foreign body sensation caused by intraocular implants. The operation time is relatively short, the surgical technique is easy to master, and the TM resection scope can be determined based on the patient’s condition. It can be used to treat some clinically meaningful glaucoma. This article is organized as follows. We present the following article following the Narrative Review reporting checklist.

Original Article
Review Article

Navigation technology/eye-tracking in ophthalmology: principles, applications and benefits—a narrative review

:-
 

Abstract: Navigation technology in ophthalmology, colloquially called “eye-tracking”, has been applied to various areas of eye care. This approach encompasses motion-based navigation technology in both ophthalmic imaging and treatment. For instance, modern imaging instruments use a real-time eye-tracking system, which helps to reduce motion artefacts and increase signal-to-noise ratio in imaging acquisition such as optical coherence tomography (OCT), microperimetry, and fluorescence and color imaging. Navigation in ophthalmic surgery has been firstly applied in laser vision corrective surgery and spread to involve navigated retinal photocoagulation, and positioning guidance of intraocular lenses (IOL) during cataract surgery. It has emerged as one of the most reliable representatives of technology as it continues to transform surgical interventions into safer, more standardized, and more predictable procedures with better outcomes. Eye-tracking is essential in refractive surgery with excimer laser ablation. Using this technology for cataract surgery in patients with high preoperative astigmatism has produced better therapeutic outcomes. Navigated retinal laser has proven to be safer and more accurate compared to the use of conventional slit lamp lasers. Eye-tracking has also been used in imaging diagnostics, where it is essential for proper alignment of captured zones of interest and accurate follow-up imaging. This technology is not routinely discussed in the ophthalmic literature even though it has been truly impactful in our clinical practice and represents a small revolution in ophthalmology.

其他期刊
  • 眼科学报

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
  • Eye Science

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
出版者信息